Instruction manual

Thermo Scientific Rotary Microtome Microm HM 340 E
Microm International GmbH
part of Thermo Fisher Scientific
Otto-Hahn-Str. 1A
69190 Walldorf / Germany
387831 - English
25
3-5 CUTTING MOVEMENT AND
RETRACTION
The cutting movement of the microtome is
generated by turning the hand wheel.
To start the cutting movement of the
microtome, turn the hand wheel.
As the specimen moves down, sectioning is
carried out (cutting movement, fig. 15.2).
Continue turning the hand wheel to bring the
specimen back up (fig. 15.4).
To protect the knife and specimen during
return travel, the specimen is retracted (R).
The yellow LED RETRACTION (fig. 16.1) lights
up. If desired, the function <retraction> can be
turned off.
Fig. 15
X=selected section thickness
1=specimen
2=cutting movement
3=knife
4=return travel
R=retraction
Fig.16
1