Instruction manual
Thermo Scientific Rotary Microtome Microm HM 340 E
Microm International GmbH
part of Thermo Fisher Scientific
Otto-Hahn-Str. 1A
69190 Walldorf / Germany
387831 - English
24
3-4-2 FINE FEED
After having adjusted knife and specimen as well
as having trimmed the specimen, sectioning can
be started.
• Press the control knob (fig. 13.1) to select the
fine section thickness setting.
• In the operating mode NORMAL, a rim is
shown on the display around the FINE value
(fig. 14.1).
• When this mode is activated, turn the knob to
alter the value.
• Turn the handwheel in a clockwise direction to
feed the specimen at the selected section
thickness.
• The same process is carried out when the
motor drive for the cutting movement is turned
on.
• The handwheel on the right side of the
instrument rotates.
Fig. 13
Fig. 14
Retraction
MEMO
MENU
1
2
FINE= 9
TRIM= 30
SUM = 0
R : ON
0
1