Specifications
SPEC No.
LC99213A
MODEL No.
LM10V332
PAGE
14
7. Optical Characteristics
Following spec are based upon the electrical measuring conditions, on which the contrast of
perpendicular direction(θx = θy = 0°) will be MAX..
Ta=25℃,V
DD
=5.0V,V
CON
-V
SS
=Vmax
Table 8
Parameter Symbol Condition MIN. TYP. MAX. Unit Remark
θx θy = 0 °
-30
-
30 deg.
Viewing angle range
θy
Co>5.0
θx = 0 °
-15
-
25 deg.
Note 1)
Contrast ratio Co
θx =θy = 0 °
35 50
- -
Note2)
Rise
τr θx =θy = 0 ° -
220 300 ms Response
time
Decay
τd θx =θy = 0 ° -
80 100 ms
Note3)
x
θx =θy = 0 ° -
0.275
- -
y
θx =θy = 0 ° -
0.320
- -
Fig.4 Definition of Viewing Angle
Note 1) The viewing angle range is defined as shown Fig.4.
Note 2) Contrast ratio is defined as follows:
Co
Luminance(brightness) all pixes "White" at Vmax
Luminance(brightness) all pixes "dark " at Vmax
=
Vmax is defined in Fig.6.
Note 3) The response characteristics of photo-detector output are measured as shown in Fig.7, assuming
that input signals are applied so as to select and deselect the dot to be measured, in the optical
characteristics test method shown in Fig.5.
+ θ x-θ x
- θ
y
+ θ y
+ θ y
- θ y
+ θ x-θ x
- θ
y
+ θ y
+ θ x
- θ x