Specifications
Configure the Furnace
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal injury or
death.
To route the vent pipe and combustion air pipe through the
furnace, the manufacturer supplied kit must be used. Failure
to properly seal the blower compartment from the furnace
vestibule could result in the circulation of carbon monoxide
throughout the structure. The vent pipe and combustion air
pipe must be a continuous pipe while passing through the
blower compartment. Seals supplied in this kit must be
installed per the instructions provided. Follow all procedures
outlined in these instructions.
With the furnace installed in the required position, remove the
desired knockouts from the casing. It will be necessary to
remove one knockout for the vent pipe and the other knockout
for the combustion air connection.
Use a flat blade screwdriver and tap on the knockout on
opposite sides, where the knockout meets the casing. Fold the
knockout down with duct pliers and work the knockout back
and forth until it is removed. Trim any excess metal from the
knockout with tin snips.
The vent elbow can be rotated to the required location on the
casing if necessary. See Figure 54 To rotate the vent elbow:
1. Loosen the clamp on the inlet of the vent elbow attached
to the inducer.
2. Rotate the vent elbow to the required position. There are
rounded notches in the vent elbow to align it with the
inducer for each orientation.
3. Tighten the clamp around the vent elbow. Torque the
clamp to 15 Ib-in. See Figure 40 through Figure 45,
Figure 55 and Figure 56.
Figure 54 JInducer Vent Elbow - Variable
!
MODULATING INDUCER ASSEMBLY
Representative drawing only, some models may vary in appearance
VENT ELBOW CLAMP
TORQUE 15 LB IN
Figure 55 _Horizontal Left Vent Configuration
HORIZONTAL LEFT VERTICAL VENT M1327
Representative drawing only, some models may vary in appearance
HORIZONTAL LEFT, LEFT VENT
Representative drawing only, some models may vary in appearance
Al1328
--I
J
HORIZONTAL LEFT, RIGHT VENT
Representative drawing only, some models may vary in appearance