Specifications

ii,lii! ii i iit ¸
Figure 43 _Downflow Left Vent
Rotate vent elbow to
required position.
®
DOWNFLOW LEFT CONFIGURATION
©
(_) Attach vent pipe adapter with gasket to furnace casing.
(_) Align notches in rubber coupling over standoffs on adapter. Slide clamps over the coupling.
G) Slide vent pipe through adapter and coupling into vent elbow.
(_) Insert vent pipe into vent elbow.
C) Torque all clamps 15 lb.-in.
(_ Attach combustion air pipe adapter with gasket to furnace.
(_) Attach combustion air pipe to adapter with silicone. Pilot drill a 1/8-in.
hole in adapter and secure with a #7 x 1/2-in sheet metal screw.
Representative drawing only, some models may vary in appearance.
Figure 44
Downflow Right Vent
Rotate vent elbow to
required position.
Al1311
Any
knockout may be used
for combustion air
connection.
(9
DOWNFLOW RIGHT CONFiGURATiON
(_) Attach vent pipe adapter with gasket to furnace casing.
(_) Align notches in rubber coupling over standoffs on adapter. Slide clamps over the coupling.
(_ Slide vent pipe through adapter and coupling into vent elbow.
(_) Insert vent pipe into vent elbow.
(_) Torque all clamps 15 lb.-in.
Q Attach combustion air pipe adapter with gasket to furnace.
(Z) Attach combustion air pipe to adapter with silicone. Pilot drill a 1/8-in.
hole in adapter and secure with a #7 x 1/2-in sheet metal screw.
Al1312
Representative drawing only, some models may vary in appearance.
440 01 4201 01 Speoificati..... bject to change without notice. 35