Specifications

ii,lii! ii i iit ¸
Figure 39 (CONT.) [Variable Speed Furnace Control for ECM Blower Motor (Modulating)
COMMUNICATION
CONNECTOR
MODEL PLUG
SWITCHES AND
BLOWER OFF-
DELAY
CONTINUOUSFAN OUTDOOR SW4SETUP
(CF) AIRFLOW AIR TEMP SWITCHES
SETUPSWITCHES CONNECTOR
PL8-MODULATING
GAS VALVE
CONNECTOR
AIR CONDITIONING _ //"
(A/C) AIRFLOW
SETUP SWITCHES HUMIDIFIER
i PL8 _ _ TERMINAL (24-VAC
0.5 AMP MAX.
24-V THERMOSTAT J ACR_J
TERMINALS "_ _ -oF_
/ D_L O_ FLASH
1 _ '_ _ UPGRADE
1 X CONNECTOR
1 _ _ (FACTORY
STATUSANDCOMM/ _i _ "_ I:11
LED LIGHTS m_r__COMM _1 oll
_1 -I-=11 ,,
- PL3 - ECM BLOWER
3-AMP FUSE SEC-2 s___ I=II [--I HARNESS
. _ I []II I I I I CONNECTOR
EAC-2 EACh1
TRANSFORMER 4VAC O I=z= I I I I
CONNECTIONS _ _I / _ PL2
r-q r-q
== I-[
_V Iv_7,_4=FZ044=4_=f--" I vsHSIHI LO_*_
115-VAC (L2) NEUTRAL -._ _ -,7 ' _ -- | '
CONNECTIONS _ /4,ojr T \
PL1- LOW VOLTAGE MAIN / _ / PART NUMBEwRwAyND / _ PL2-HOT SURFACE
HARNESS CONNECTOR / _ IGNITER & INDUCER
SOFTWARE EAC-1 TERMINAL 115-VAC (L1) LINE MOTOR CONNECTOR
VERSION (115-VAC 1.0 AMP MAX.) VOLTAGE CONNECTIONS
Lll F061
VENTING
Furnace is set in place in the required orientation.
Special Venting Requirements for Installations
in Canada
Installation in Canada must conform to the requirements of
CAN/CSA B149 code. Vent systems must be composed of
pipe, fittings, cements, and primers listed to ULC S636. The
special vent fittings and accessory concentric vent termination
kits and accessory external drain trap have been certified to
ULC S636 for use with those Royal Pipe and IPEX PVC vent
components which have been certified to this standard. In
Canada, the primer and cement must be of the same
manufacturer as the vent system - GVS-65 Primer (Purple) for
Royal Pipe or IPEX System 636, PVC/CPVC Primer, Purple
Violet for Flue Gas Venting and GVS-65 PVC Solvent Cement
for Royal Pipe or IPEX System 636(1)t, PVC Cement for Flue
Gas Venting, rated Class IIA, 65 deg C. must be used with this
venting system - do not mix primers and cements from one
manufacturer with a vent system from a different manufacturer.
Follow the manufacturer's instructions in the use of primer and
cement and never use primer or cement beyond its expiration
date.
The safe operation, as defined by ULC S636, of the vent
system is based on following these installation instructions, the
vent system manufacturer's installation instructions, and proper
use of primer and cement. All fire stop and roof flashing used
with this system must be UL listed material. Acceptability under
Canadian standard CAN/CSA B149 is dependent upon full
compliance with all installation instructions. Under this
standard, it is recommended that the vent system be checked
once a year by qualified service personnel.
The authority having jurisdiction (gas inspection authority,
municipal building department, fire department, etc) should be
consulted before installation to determine the need to obtain a
permit.
*IPEX System 636 TM is a trademark of IPEX Inc.
Consignes sp_ciales pour I'installation de
ventilation au Canada
L'installation faite au Canada dolt se conformer aux exigences
du code CAN/CSA B149-2010. Ce syst_me de ventillation dolt
se composer de tuyaux, raccords, ciments et appr_ts
conformes au ULC S636. La tuyauterie de ventillation des gaz,
ses accessoires, le terminal concentrique mural ainsi que
I'ensembte du drain de condensat exterieur ont et6 certifies
ULCS 636 pour I'application des composantes Royal Pipe,
IPEX PVC qui sont certifiees & ce standard. Au Canada,
I'appr_t et le ciment doivent _tre du m_me fabricant que le
systeme d'evacuation. Uappr_t GVS-65 (Purple) et le
ciment-solvant GVS-65 doivent _tre utilise avec les Royal Pipe.
Systeme IPEX 636, appr_t PVC/CPVC, Purple pour
evacuation des gaz de combustion et systeme IPEX 636(1)t,
ciment PVC pour evacuation des gaz de combustion, cote
classe IIA, 65 deg C. doivent _tre utilises avec le systeme
d'evacuation IPEX 636 - Ne pas combiner I 'appr_t et le ciment
d'un manufacturier avec un systeme d'evacuation d'un
manufacturier different.
440 01 4201 01 Specificati ..... bject to change without notice. 31