Figure 10 1Unconverted Factory Configuration as viewed in the Horizontal Left orientation
Remove trap from
collector box.
If alternate vent position
is required, loosen clamp Remove relief tube
on vent elbow inlet, from relief port on
condensate trap.
Remove pressure switch tube
from port on collector box.
Remove relief tube
from port on collector
box.
Remove middle and right
plug from collector box.
(MODULATING UNITS)
Representative drawing only some models may vary in appearance.
Horizontal Left Trap Configuration
Rotate elbow to
desired position and
torque clamp on inlet
15 Ib.-in.
Install plugs in open
ports on collector box.
Connect relief tube to
port on collector box.
Slide relief tube in
stand-offs to adjust
length.
Attach condensate
trap to collector box
with screw.
Trim excess tube.
Route pressure switch tube
underneath relief tube and
connect to port on collector box.
Align trap over middle
and right-hand port on
collector box.
(MODULATING UNITS)
Connect relief tube to
relief port on condensate trap.
Representative drawing only some models may vary in appearance.
Al1282