Technical data

13773-001
27-10
Page 7
Figure 27-102
Aileron Gap Overlap Inspections
30 Nov 2000
Minimum Maximum Min. at Actuation Arm Max. Adjacent to
Aileron Cove
Leading Edge Gap
0.110"
2.8 mm
0.200"
5.1 mm
0.125"
3.2 mm
-
Overlap
0.010"
0.25 mm
0.125"
3.2 mm
--
Neutral Position Gap
0.060"
1.5"
0.210"
5.3 mm
- 0.150"
3.8 mm