Note: While tightening bridal clamp to elevator cable, capstan will rotate. Offset
this rotation while adjusting opposite bridal cable tension so that when
specified tension is reached, the middle spanner adapter tooling hole is at
the 12 oclock position (stop-ball at top of capstan).
(i) At aft bridal clamp assembly, push clamp assembly aft while tightening clamp to elevator
cable.
(j) Using the techniques described above, adjust bridal cable tension to 17.0 +/- 4.0 lb (7.7 +/
- 1.8 Kg).
(k) Remove lock-out pin.
(l) Install access panel RE1. (Refer to 6-00)