Technical data
13773-001
80-10
Page 1
CRANKING
1. DESCRIPTION
This section describes that portion of the system used to perform the cranking portion of the starting oper-
ation.
2. MAINTENANCE PRACTICES
A. Starter (See Figure 80-101)
(1) Removal - Starter
(a) Ensure BAT 1, BAT 2, and AVIONICS master switches are in off position.
(b) Pull STARTER RELAY circuit breaker.
(c) Remove engine cowling. (Refer to 71-10)
(d) Disconnect positive battery cable at battery.
(e) Disconnect electrical cable at starter motor.
(f) Remove starter in accordance with Teledyne Continental Motors Model IO-550 Overhaul
Manual indexed in the List or Publications in the front of this manual. (Refer to TCM Model
IO-550 Overhaul Manual)
(2) Installation - Starter
(a) Install starter in accordance with Teledyne Continental Motors Model IO-550 Overhaul
Manual indexed in the List or Publications in the front of this manual. (Refer to TCM Model
IO-550 Overhaul Manual)
WARNING:
Prior to connecting power to starter, ensure ignition switch is in OFF
position, wheels are chocked, throttle is set to IDLE, and mixture is set
to CUTOFF.
(b) Connect electrical cable to starter motor.
(c) Connect positive cable at battery.
(d) Install engine cowling. (Refer to 71-10)
(e) Reset STARTER RELAY circuit breaker.
30 Nov 2000