The ELI 250 automatically analyzes ECGs and prints the optional interpretation on the ECG printout. This option
allows you to select or suppress the “interpretive” text on the ECG report.
NOTE: A qualified physician should review the computer generated ECG interpretation before the
treatment of any patient.
Reasons
The reason statements indicate why a particular interpretive statement was printed. Reason statements print in
[square brackets] within the interpretive text (if the interpretation is turned on). Turning the reason statement
function on or off does not affect the measurements performed or the interpretive statements selected by the analysis
program.
For Example:
Anteroseptal Infarct [40+ MS Q WAVE IN V1-V4]
Where “Anteroseptal Infarct” is the interpretive statement.
And “40+ MS Q WAVE IN V1-V4” is the reason statement or explanation as to why the
interpretive statement was printed.
Configuration Page 3
Append
A status or statement phrase can be appended to the ECG and printed under the interpretive text printout. Either
“unconfirmed report” or “reviewed by” can be selected. However, if you wish to have nothing appended to the
ECG, “blank” may be selected.
Number of Copies
This option defines the number of printed copies when an ECG is taken. A zero (0) setting prints the original only;
one (1) prints the original plus 1 copy; two (2) prints the original plus 2 copies, and so on. Up to 9 copies may be
selected.
ECGs Retrieved