Specifications
Ver SG 9/200 58 Sharp Electronics Corporation
(B) HORIZONTAL EXHAUST: Outside Ventilation
1. Remove and save 2 screws from back edge and 1 screw from the top center of Fan
Cover Bracket. Remove Fan Cover Bracket by sliding it in the opposite direction of the
arrow on the Fan Cover Bracket, as shown in Figure 9.
2. Withdraw Hood Fan Unit carefully and slip wires out of Wire Box. See Figure 10.
CAUTION: Do not pull or stretch hood fan wiring.
3. Rotate the Hood Fan Unit and turn end-over-end so that the fan blade openings are
facing the back of the oven. Replace Hood Fan Unit into the oven. Be careful not to pinch
the lead wire between the inner bracket and the Hood Fan Unit. See Figure 11.
4. Put the lead wire into Wire Box. See Figure 12.
5. Replace the Fan Cover Bracket by sliding it into the slits in the same direction as the
arrow on the Fan Cover Bracket. Make sure the fan blades are visible through the rear
openings in the oven before proceeding. Attach Fan Cover Bracket to unit with 3 screws,
which were removed in Step 1 above. See Figure 12. The Hood Fan Unit is now rotated
for horizontal exhaust operation.
6. Attach the Exhaust Damper Assembly 8 to the back of the Mounting Plate by sliding it
into the slits in the same direction as the arrow. See Figure 13. Using Tapping Screw 4 X
12 7 from the INSTALLATION HARDWARE, tighten into place.