Specifications

Ver SG 9/200 57 Sharp Electronics Corporation
8. VENTILATION SYSTEM
This Microwave Oven/Hood is designed for adaptation to three types of hood ventilation
systems. Select the type required for your installation.
A. Recirculatingnon-vented, ductless. Follow installation procedure A. Recirculating
requires the use of the Charcoal Filter 9, which is packed under the oven in the carton.
B. Horizontal Exhaustoutside ventilation. Follow installation procedure B
C. Vertical Exhaustoutside ventilation. Follow installation C
(A) RECIRCULATING: Non-Vented, Ductless Operation
The unit is shipped assembled for recirculating. Attach the Charcoal Filter to the upper
side of the oven by sliding into the tabs. See Figure 8.
NOTE:
1. The Exhaust Damper Assembly 8 is not required for recirculating operation.
2. The Charcoal Filter should be replaced every 6 to 12months, depending on use.
3. The Charcoal Filter RK-230 is also sold as an accessory.
Figure 8