Specifications

Ver SG 9/200 42 Sharp Electronics Corporation
Thermistor Test
1. Disconnect the power supply cord and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect connector-D from the control unit. Measure the resistance of the
thermistor with an ohmmeter. Connect the ohmmeter leads to Pin #s D1 and D3.
Room Temperature Resistance
68 degrees F - 86 degrees F Approx. 293k ohms - 184k ohms
5. If the meter does not indicate above resistance, replace the thermistor.
6. Reconnect all leads removed from components during testing.
7. Reinstall outer case cabinet.