Specifications

Ver SG 9/200 26 Sharp Electronics Corporation
If the water temperatures are accurately measured and tested for the required time period,
the tests results will indicate if the magnetron tube has low power output (low rise in
water temperature), which would extend the cooking time, or a high power output (high
rise in water temperature), which would decrease the cooking time. Because cooking
time can be adjusted to compensate for power output, the magnetron tube should not be
replaced unless the water temperature rise test indicates a power output well above or
below the normal limits.
Test results are only accurate if the power supply line voltage is 120 volts and the oven
cavity is clean.