Service manual

QT-CD250H/W
– 24 –
IC51 VHiLC72121/-1: Electronic Tuning (LC72121) (1/2)
1 Xtal XIN Output Crystal oscillator connection.(4.5 MHz/7.2 MHz)
2 Ground VSSX Output Ground terminal for the crystal oscillation circuit system of LC72121.
3 Chip enable CE Output High level when inputting serial data (DI) to LC72121 or sending
serial data (DO).
4 Input data DI Input Input terminal for serial data that is transferred from the controller to
LC72121.
5 Clock CL Output Clock that synchronizes data when inputting serial data (DI) to
LC72121 or sending serial data (DO).
6 Output data DO Output Output terminal that sends data from LC72121 to the controller. The
output data is defined by serial data DOC0-DOC2.
7* Output port BO1 Output Output dedicated terminal.
Output state is defined by the serial data BO1-BO4.
Data 0: Open
Data 1: L
Time base signal (8 Hz) output is possible from BO1 terminal.
(When setting serial data TBC = 1.)
8-10 Output port BO2-BO4 Output Output dedicated terminal.
Output state is defined by the serial data BO1-BO4.
Data 0: Open
Data 1: L
Time base signal (8 Hz) output is possible from BO1 terminal.
(When setting serial data TBC = 1.)
11 Input/output port IO1 Input/Output Terminal for both input and output.
Input and output are defined by serial data IDC1 and IOC2.
Data 0: Input port
Data 1: Output port
When specified as the input port.
The input terminal state is transferred from the DO terminal to the
controller.
Input state "L": Data -> 0
Input state "H": Data -> 1
When specified as the output port.
Output state is defined by the serial data IO1 and IO2.
Data 0: Open
Data 1: L
When turning on the power or resetting, the terminal becomes the
input port.
12 IF counter IF IN Input Input frequency is 0.4-12 MHz.
Signal is transferred to the IF counter directly.
The result is sent from M5B of the IF counter through DO.
4 measuring times: 4, 8, 32, and 64 ms
13 Input/output port IO2 Input/Output Terminal for both input and output.
Input and output are defined by serial data IDC1 and IOC2.
Data 0: Input port
Data 1: Output port
When specified as the input port.
The input terminal state is transferred from the DO terminal to the
controller.
Input state "L": Data -> 0
Input state "H": Data -> 1
When specified as the output port.
Output state is defined by the serial data IO1 and IO2.
Data 0: Open
Data 1: L
When turning on the power or resetting, the terminal becomes the
input port.
14 Ground VSSD Ground terminal for the digital system other than VSSA and VSSX of
LC72121.
Port Name
Terminal
Name
Pin No.
Input/Output
Function
FUNCTION TABLE OF IC
In this unit, the terminal with asterisk mark (*) is (open) terminal which is not connected to the outside.