Instruction manual
82 
Possible cause: 
b)  The temperatures at the measuring point on the ECG or at the cool 
  spot on the lamp(s) are exceeded (for a brief description of the 
  temperature at the ECG and lamp see end of text). 
 Remedy: 
  The luminaire or site of installation should be modified to ensure 
  that the maximum recommended temperature is not exceeded 
  even in onerous conditions circumstances (high ambient 
  temperature and/or high supply voltage). 
8.5.4 Different brightness 
levels 
Problem: 
Luminous output too low compared with other luminaires. Different 
brightness levels for the two lamps in two-lamp luminaires. Different 
brightness levels at the lamp ends 
Possible cause: 
a)  Typical maintenance behaviour of a fluorescent lamp at the end of 
 its life 
Remedy: 
  Replace the lamp (for two-lamp ECGs we recommend replacing 
  both lamps at the same time to keep maintenance time and costs 
  to a minimum). 
Possible cause: 
b)  Lamps of different wattages colour appearance or incorrect 
 wattage 
Remedy: 
  The lamp wattage must match the wattage indicated on the ECG. 
  The colour appearande should be homogenous within an 
 application. 
Possible cause: 
c)  Incorrect wiring between ECG and lamp (output terminals not used 
  or reversed; contact problems) 
Remedy: 
  Check the lamp-side wiring for correct contact. Has the lamp 
  connection been wired according to the wiring diagram on the EG? 
  For two-lamp ECGs in particular, check that the common or 
  external connection is correctly wired. Pay particular attention in 
  the case of special combinations. 
Possible cause: 
d)  Lamps are “force cooled” by draughts 
Remedy: 
  Find the cause of the draught and either eliminate the draught or 
  protect the lamps accordingly. 