Instruction manual
3 
3.9.2.1
  Measuring Point Temperature tc................................42 
3.9.2.2  Ambient Temperature ECG : ta..................................43 
3.9.3  Lamp Temperature ...............................................................43 
3.9.3.1  Maximum Luminous Flux for T5/∅ 16 mm-Fluorescent 
Lamps ........................................................................43
3.9.4  General Recommendations for Installation...........................44 
3.9.5  Measuring the Temperature .................................................44 
3.10  Luminaire Wiring Test for Two-lamp Luminaires ..................45 
3.10.1 Testing with a Test Adapter and Dummy Lamps..................45 
3.11  ECG Operation for Luminaires of Protection Classes I and II48 
3.12  Insulation Distances in Luminaires .......................................48 
3.13  Insulation Test ......................................................................48 
3.13.1 Dielectric Resistance in Lighting Systems ............................49 
3.13.2 Mesuring the Dielectric Resistance between N and PE or L 
and PE..................................................................................49
3.13.3 Three-Phase Operation ........................................................50 
3.13.4 Resistance to Overvoltage for QUICKTRONIC for 
T5/∅16mm- Fluorescent Lamps...........................................50
3.14  Inrush Current / Automatic Circuit Breakers .........................50 
3.15  RCDs / Fault Currents ..........................................................51 
3.16  Leakage Current...................................................................51 
3.17  ECGs in Three-Phase Operation..........................................51 
4.  Lamp Wiring.......................................................................................53 
4.1  h = 21 mm.............................................................................53 
4.1.1  QUICKTRONIC
®
 INTELLIGENT 1-lamp version ..................53 
4.1.2  QUICKTRONIC 
® 
INTELLIGENT 2-lamp version .................53 
4.1.3  QT-FH MULTIWATT F/CW...................................................53 
4.1.4  QT-FQ F/CW 1-lamp version................................................53 
4.1.5  QT-FQ F/CW 2-lamp version................................................54 
4.2  h= 30 mm..............................................................................54 
4.2.1  QT-FH MULTIWATT 1- and 2-lamp version .........................54 
4.2.2  QT-FH 3- and 4-lamp version...............................................54 
4.2.3  QT-FQ 1-lamp version..........................................................55 
4.2.4  QT-FQ 2-lamp version..........................................................55 
5.  QUICKTRONIC INTELLIGENT...........................................................56 
5.1  Definition INTELLIGENT.......................................................56 
5.2  Lamp Detection as Fundamental Advantage........................56 
5.3  QTi – the High-tech ECG......................................................56 
5.4  QTi – Advantages.................................................................56 
5.5  QTi – Practically Applied.......................................................57 
5.6  Technical Specialties for non-dimmable QTi ........................57 
5.6.1  Inrush current limitation ........................................................57 
5.6.2  Resistance to Overvoltage up to 400V .................................58 
5.6.3  Lamp-ECG-Combination ......................................................58 
5.6.3.1  Straight Fluorescent types .........................................58 
5.6.3.2  Compact and Circular lamp types..............................59 
5.6.4  Wiring ....................................................................................59 