Instruction manual
2 
2.15
  End of Life (EoL acc. to T.2)................................................22 
2.16  U-OUT ..................................................................................22 
2.17  Approval Marks.....................................................................23 
2.17.1 ENEC-Approval Mark ...........................................................23 
2.17.1.1 Safety acc. to EN 61347 ............................................23 
2.17.1.2 Performance acc. to EN 60929..................................23 
2.17.2 VDE EMC mark ....................................................................23 
2.18  Energie Efficiency Index EEI ................................................24 
2.19  CE Labelling .........................................................................24 
2.20  CCC Approval.......................................................................25 
3.  ECG installed in Luminaire: Installations and Operation 
Instructions 26
3.1  Wiring Instructions ................................................................26 
3.1.1  Cable Types..........................................................................26 
3.1.2  Cable Cross-Sections...........................................................26 
3.1.2.1  ECG in 30 mm height.................................................27 
3.1.2.2  ECG in 21 mm height.................................................27 
3.1.3  Release of Contacts .............................................................27 
3.1.3.1  WAGO 250.................................................................27 
3.1.3.2  WAGO 251 – IDC.......................................................27 
3.1.3.3  WAGO 251 – horizontal plug .....................................28 
3.1.3.4  WAGO 251 mini – IDC...............................................28 
3.1.3.5  WAGO 251 mini – horizontal plug..............................28 
3.1.4  Insulation ..............................................................................29 
3.1.5  Terminals..............................................................................29 
3.1.6  Cable routing ........................................................................29 
3.2  Electromagnetic Compatibility ..............................................30 
3.2.1  Harmonic Content acc. to EN 61000-3-2..............................30 
3.2.2  Radio interference suppression............................................31 
3.2.2.1  Causes of Radio Interference ....................................31 
3.2.2.2  Conducted Interferences acc. to EN 55015 ...............31 
3.2.2.3  Disturbances due to Fields.........................................32 
3.2.2.4  Selective Shielding.....................................................32 
3.2.2.5  Installation Instructions for avoiding Disturbance.......33 
3.2.2.6  Asymmetric installation of ECG..................................34 
3.2.2.7  Good wiring arrangement for 2-lamp luminaires........35 
3.2.2.8  Luminaires with reflector and/or specular louvres......35 
3.3  Permissible Cable Lengths...................................................36 
3.4  „Hot Wires“............................................................................36 
3.5  Switching between Lamp and ECG......................................37 
3.6  Master-Slave Circuit .............................................................37 
3.6.1  Max. length of the connecting cable between 2 luminaries ..38 
3.7  PE-Connection for Protection Class I Luminaires.................38 
3.8  Functional Earth for Luminaires of Protection Class II.........39 
3.8.1  General Information..............................................................40 
3.8.2  Practical Details....................................................................40 
3.9  Temperature Ranges............................................................41 
3.9.1  Self heating ECG..................................................................41 
3.9.2  Control Gaer Temperatures..................................................42 