Instruction manual

12 
2. Product Features 
2.1 Lighting Comfort 
•  Flicker-free ignition 
•  Pleasant, flicker-free light with no stroboscopic effects due to high 
frequency operation 
•  High comfort level with no distracting choke hum due to fully 
electronic operation (see chapter 2.8 noise) 
•  No flickering 
•     No flashing or flickering, electronic defective control for 
reliable safety switch-off of defective lamps 
End-of-life safety shut down 
•     Cut-off of the permanent filament preheating after lamp 
ignition 
•  Automatic restart after lamp replacement 
2.2 Economy 
•  High lumen packages for T5 FQ
®
 High Output system 
•  Very high luminous efficacy for T5 FH
®
 High Efficiency system 
•  Long lamp life due to lamp start with optimum filament pre-heating 
and operation with cut-off technology 
•  Low maintenance costs due to long lamp life and reduced relamping 
intervals 
•  Lower cooling load of air-conditioning systems due to lower losses 
2.3 Safety 
All Electronic Control Gear QUICKTRONIC
®
 for operation of T5/∅ 16 mm- 
fluorescent lamp systems are developed and designed according to all 
relevant national and international industry standards. 
Current standard is EN 61347. For Electronic Control Gear for operation of 
low pressure gas discharge lamps EN 61347-2-3 applies. 
Light engineering with T5 (Ø 16 mm) lamps
012344,5 m
0
1
2
3
4
Büro mit 4 1-flammigen Leuchten
Office with 4 single tube luminaires
Leuchte/ 1xL58 W 1xL58 W 1xFH35 W
Luminaire
Vorschaltgerät/ VVG/ EVG/ EVG/
Control Gear LLG ECG ECG
E [lux] 539 518 500
P
gesamt/total
[W] 260 220 154
% 100 % 85 % 59 %
W/m
2
15 12 9