Instruction manual
10 
life. Electronic Control Gear improve the efficiency and the lamp life of 
fluorescent lamps significantly. 
1.7  Ignition of Fluorescent 
Lamps 
Prior to ignition, modern ECG heat the cathode to its optimum temperature 
for electron emission. After a defined period the lamp is ignited with the 
required ignition voltage. Only an optimized preheat start can guarantee 
that the number of switching cycles has only little effect on the lamp life. 
This is another important feature of ECG which has a positive effect on the 
cost of operation and which should not be neglected when looking for 
alternatives to CCG. 
1.8  Costs and Safety 
At the end of lamp life the emitter paste applied to the lamp electrode is 
used up. The complete loss of emitter results in an increase of voltage in 
the vicinity of the electrode. This situation can last over a longer period of 
time. As an immediate result of the accompanying temperature increase at 
the lamp ends the lamp sockets may overheat. Modern ECG are able to 
detect this malfunction and switch the lamps off. Unnecessary attempts to 
ignite are avoided by an interrupting function and therefore, also 
overheating is avoided - an important contribution to more safety. 
Professional ECG control all parameters constantly. A safety shut down at 
the end of the lamp life is mandatory from January 1
st
, 2007 on for all ECG 
that operate T4 or T5 tubes as it is included in the IEC 61347 
(Omnibusnorm for safety of Electronic Control Gear). For several years 
now, all OSRAM QUICKTRONIC
®
 fulfill the safety requirements acc. the 
IEC 61347 already. 
However as there was no Standard for this before, some ECG 
manufacturer neglect this due to costs. 
1.9 Flexibility upon 
Request 
During past years, we see a clear increase in new, better and more energy 
efficient lamp systems. Unfortunately, this resulted also in a growing 
number of various ECG-types. To reduce this large number of types 
manufacturers of ECG have taken a new direction and have developed 
new multi-purpose ECG which can be used for a variety of fluorescent 
lamps of different wattages. New integrated circuits allow the optimum 
control of lamp features such as lumen output. This type reduction has, of 
course, a big effect on the customer: ordering, warehousing and installation 
of only a few ECG-types. The so-called MULTIWATT-ECG reduce all 
relevant cost drivers. 
1.10  ECG bring Progress 
In addition to the basic tasks of lamp operation which are also fulfilled by 
magnetic ballasts, Electronic Control Gear have much more to offer: They 
have better performance and are more reliable, more environmental 
friendly and more practical than CCG; even more reasons to use 
professional Electronic Control Gear. 
1.11  The right ECG for every 
Application 
OSRAM offers the right Electronic ballast for every application as shown at 
the example of T8/ ∅ 26 mm fluorescent lamps. 