Service manual

14
PZ-43HV2, PZ-43HV2E
PZ-43HV2U
11
11
×2
8
×2
8
7
Remove the Rear Case (P). (Screws × 19)
9
Remove the Front Chassis V. (Screws × 5)
8
Remove the Y DRIVE Assy.
(Connector, PCB Spacer × 3, Screws × 8)
10
Remove the Scan IC Spring (43L) and (43R).
(Screws × 1)
Reverse the SCAN (A) and SCAN (B) Assemblies.
12
11
When it is necessary, exchange the ROM.
Y DRIVE Assy
SCAN (A) Assy
ROM
×6
SCAN (B) Assy
8
8
8
8
8
1
Remove the three screws.
2
2
Loosen a rivet.
3
3
Remove the Lead Cover (P).
Turn it not to press the rivet.
(Because when the rivet presses,
fit in once again.)
It is easy to remove when pull out
the Lead Cover (P) with the rivet
before completely removing the rivet.
Rivet
4
Pull out a Flexible Cable.
5
5
Remove bottom by the fulcrum at the top of Front Case
Assy 43 (P).
6
6
Remove the Front Case Assy 43 (P).
×3
Y DRIVE, SCAN (A), (B) Assy
1
Front Case Assy 43 (P)
Front Case Assy 43 (P)
Aluminum
Materials
It is the structure that a hook of
Front Case Assy 43 (P) was put between
with Rear Case and aluminum materials.
Rear Case
Lead Cover (P)
Lead Cover (P)
44
Scan IC Spring (43L)
Scan IC Spring (43R)
10
9
9
9
9
9