47
E
MONITOR menu
Function
Command Direction
Parameter Reply Control/Response contents *
PORTRAIT/LANDSCAPE INSTALL STDR WR 0-1 0-1 0: LANDSCAPE, 1: PORTRAIT
○
ROTATE 180°/PICTURE FLIP PFIL WR 0, 2, 3 0, 2, 3 0: ROTATE 180° is set to OFF. PICTURE FLIP is set to OFF.
2: ROTATE 180° is set to OFF. PICTURE FLIP is set to ON.
3: ROTATE 180° is set to ON. PICTURE FLIP is set to OFF.
“ERR” when PIP MODES is a value other than OFF.
When INVERSE SCAN is set to ON, can not set to 3 “ERR”.
When INVERSE SCAN is set to OFF, can not set to 2 “ERR”.
INVERSE SCAN INVV WR 0-1 0-1 0: OFF, 1: ON
OSD H-POSITION OSDH WR 0-100 0-100 “ERR” when PORTRAIT/LANDSCAPE INSTALL is set to PORTRAIT.
OSD V-POSITION OSDV WR 0-100 0-100
OPERATION MODE FNCM WR 0-1 0-1 0: MODE1, 1: MODE2
POWER SAVE MODE STBM WR 0-1 0-1 0: OFF, 1: ON
OFF IF NO OPERATION
ATOF WR 0-1 0-1 0: OFF, 1: ON
TIME AOFT WR 1-12 1-12 1-12: 1-12 hours
POWER ON DELAY PODS WR 0-1 0-1 0: OFF, 1: ON
INTERVAL PWOD WR 1-60 1-60 1-60: 1-60 seconds
SELF ADJUST AADJ WR 0-1 0-1 0: OFF, 1: ON
START TIMING AADD WR 10-200 10-200 10: 1 second through 200: 20 seconds
Controlling the Monitor with a computer (RS-232C)