Controlling the Monitor with a PC (RS-232C)
IDLK ........
The parameter of this command sets the ID
number of the monitor. The monitor is subject to all
subsequent commands.
Example:
IDLK0002 ←
Following commands are for the monitor
with ID number: 2.
WAIT ←
Searching for monitor with ID number:
2
OK 002 ←
Found monitor with ID number: 2
VOLM0030 ←
Sets volume of monitor with ID
number: 2 to 30.*
WAIT ←
Processing
OK 002
VOLM0020 ←
Sets volume of monitor with ID
number: 2 to 20.*
WAIT
OK
002
IDLK0000 ←
Canceling xed ID number setting
WAIT ←
Canceling IDLK
OK 002 ←
Cancelation complete
VOLM0010
OK
001 ←
The volume of the monitor with ID number:
1 (the one directly connected to the PC) is
set to 10. (IDLK is canceled.)
* The IDLK command remains effective until it is
canceled, or power is shut off.
IDCK ........Provides screen display of the ID number currently
assigned to a monitor, and the ID number currently
set for IDLK (if any).
Example:
(After executing IDLK0002)
IDCK0000
←
(Parameter has no meaning.)
ID : 001 IDLK : 002
←
Returned response. The ID
number is also displayed on the
monitor screen.
IDCK000 +
←
Repeater control. (If a command
is used with repeater control, ID
designation using IDSL or IDLK
is canceled.)
WAIT
ID : 001 IDLK : 002
ID : 002 IDLK : 002
ID : 003 IDLK : 002
ID : 004 IDLK : 002
n
Repeater control
This system has a function to allow setting of multiple
monitors connected in a daisy chain using a single command.
This function is called repeater control. You can use Repeater
control function without assigning ID numbers.
[E
xamp
l
e
]
Set 1
Set 2 Set 3Set 4
* If monitors are connected as shown above, you can
execute a command like “Set all monitors’ input settings to
PC D-SUB”.