Operation Manual

33
E
Controlling the Monitor with a computer (RS-232C)
AUDIO menu
Function
Command Direction
Parameter Reply Control/Response contents
VOLUME VOLM
WR 0-31 0-31
SETUP menu
Function
Command Direction
Parameter Reply Control/Response contents
ALL RESET RSET W
1
1: ALL RESET
PIP menu
Function
Command Direction
Parameter Reply Control/Response contents
PIP MODES MWIN WR 0-2 0-2 0: OFF, 1: PIP, 2: PbyP
PIP SIZE MPSZ WR 0-2 0-2 0: SMALL, 1: MEDIUM, 2: LARGE
PIP POS MWPS WR 0-3 0-3 0: UPPER RIGHT, 1: UPPER LEFT, 2: LOWER RIGHT, 3: LOWER LEFT
PIP SOURCE MWIP WR 2 2 D-SUB
10 10 HDMI1
13 13 HDMI2
18 18 HDMI3
23 23 HDMI4
14 14 DisplayPort
21 21 OPTION
SOUND CHANGE MWAD WR 1-2 1-2 1: MAIN, 2: SUB
RESET RPIP W 1
OTHERS menu
Function
Command Direction
Parameter Reply Control/Response contents
MONITOR LOCK ALTG WR 0-3 0-3 0: REMOTE CONTROL, 1: MONITOR BUTTONS, 2: BOTH, 3: OFF
Others
Function
Command Direction
Parameter Reply Control/Response contents
RESOLUTION CHECK PXCK R - Returns current resolution in the form of hhh, vvv.
MUTE MUTE WR 0-1 0-1 0: OFF, 1: ON
INFORMATION MODEL INF1 R Value
SERIAL NO SRNO R Value
TEMPERATURE SENSOR DSTA R 0 Internal temperature normal
1 Internal temperature abnormal has occurred and the monitor is in standby mode
2 Internal temperature abnormal occurred (To delete the information of temperature
abnormal, turn off the main power.)
3 Internal temperature abnormal has occurred and backlight brightness is dimmed
4 Temperature sensor abnormal
TEMPERATURE ACQUISITION ERRT R Value Returns the temperature at the temperature sensors.
Indicates a temperature sensor abnormality when “126” is returned.
CAUSE OF LAST STANDBY MODE STCA W 0 Initialization
R 0 No detectable error has occurred
1 Standby mode by POWER button
2 Main power off by the main power switch
3 Standby mode by RS-232C
4 Input signal waiting mode by No Signal
6 Standby mode by abnormal temperature
20 Standby mode by OFF IF NO OPERATION setting