Owner's Manual
53
Appendix
Maintenance Indicators
The warning lights (power indicator, lamp indicator and temperature warning indicator) on the
projector indicate problems inside the projector.
If a problem occurs, either the temperature warning indicator or the lamp indicator will
illuminate red, and the projector will enter standby mode. After the projector has entered
standby mode, follow the procedures given below.
Top View
Lamp indicator
Temperature warning
indicator
Power indicator
About the temperature warning indicator
If the temperature inside the projector increases, due to blockage of the air vents, or the
setting location, “ ” will illuminate in the lower left corner of the picture. If the temperature
keeps on rising, the lamp will turn off and the temperature warning indicator will blink, the
cooling fan will run, and then the projector will enter standby mode. After “ ” appears,
ensure you perform the measures described on page 54.
About the lamp indicator
When the remaining lamp life becomes 5% or less, (yellow) and “Change The Lamp” will
be displayed on the screen. When the percentage becomes 0%, it will change to (red),
the lamp will automatically turn off and then the projector will automatically enter standby
mode. At this time, the lamp indicator will illuminate in red.
If you try to turn on the projector a fourth time without replacing the lamp, the
projector will not turn on.
■
■
Indicators on the Projector
Power indicator Red on Normal (Standby)
Green on Normal (Power on)
Red blinks Abnormal (See page
54.)
Green blinks Normal (Cooling)
Lamp indicator Green on Normal
Green blinks The lamp is warming up.
Red on The lamp is shut down abnormally or requires to be
changed. (See page
54.)
Temperature warning
indicator
Off Normal
Red on The internal temperature is abnormally high. (See page
54.)
■
■