Service manual
Ver. 3/00 1-2 Sharp Electronics Corporation
HOW TO CONVERGE THE LCD PANELS (continued)
Step Procedure Ref. #
2. Removal of
body panels.
1. To remove the cabinet, refer to the service manual for the
specific model.
3. Adjustment
of the blue
panel.
1. Supply the projector with a blue and green crosshatch
signal from the pattern generator (on most video signal
generators, it is possible to remove one or more of the 3
colors making up the crosshatch signal. In this case red
must be removed. To do this refer to the instructions for
the pattern generator).
2. Use the L-shaped hex wrench to loosen the two hex screws
labeled “Lock Screw” in fig. 1.
Be sure to leave the lock screws tight enough so that when
an adjustment is made, the panel will stay in that position
until the lock screws are fully tightened after the
completion of all adjustments.
3. Use the eccentric cam wrench to adjust the Y axis (up and
down).
4. Use the eccentric cam wrench to adjust the X axis (side to
side).
5. Use the eccentric cam wrench to adjust the θZ axis
(tilt).
6. When the blue image is converged within specifications to
the green panel, tighten the two lock screws to secure the
adjustments.
NOTE: Tightening the screws may cause mis-convergence.
If this happens, readjust the affected panel.
fig. 1
fig. 1
fig. 1
fig. 1