Service manual

Ver. 3/00 2-3 Sharp Electronics Corporation
HOW TO CHANGE THE LAMP ASSEMBLY
For the models XG-E1200U, XG-E3000U, and XG-E3500U
Step Procedure Ref. #
1. Removal of
the old Lamp
Assembly.
Refer to safety notes on page S-1 in the Main Limited
Servicer Maintenance Manual before attempting to change the
lamp
1. Remove the lamp cover.
2. Remove the screws securing the lamp assembly.
3. Pull the lamp assembly out of the projector.
Safety notes: Be sure to wear Safety Glasses when
removing the lamp. Do not attempt to remove the lamp
assembly until the projector has had an ample amount of
time to cool down.( 1 hour. )
After removing the lamp assembly, do not look at the
actual lamp.
Place the lamp assembly face down. This is necessary
because the metal halide lamp is pressurized and could
explode causing injury.
fig. 4
fig. 4
fig. 4
2. Installing
the new Lamp
Assembly.
1. Insert the new assembly by pushing on it until it fits snugly
into the lamp well.
2. Install the screws into the same holes as the original lamp
assembly.
3. Re-install the lamp cover.
Note: Be sure the lamp cover is installed correctly or the
projector will not operate due to the safety switch not
being activated.
3. To reset the lamp timer, press and hold down the Enter,
Adjust Down, and Adjust Right Keys, then apply power to the
unit with the Main Power Switch on the side of the projector.
The projector should power on and display 0000Hon the
screen.
Lamp replacement is complete.
Fig 4
Fig 4
Fig 4