User`s manual
3-8
ZM-61E
Model
Item
Numerical data
display
In the setting of [Code:
BCD], display at the ZM-
61E is as shown below.
PLC side ZM-61E side
0 to 9 0 to 9
A .
B :
C -
D +
E (space)
F (space)
Possible
By checking [Num. Display: displays special charac-
ters instead of A to F in BCD] in the
[Environment Setting] tab window of [Unit Setting]
With check mark : Same display mode as with ZM-61E.
Without check mark : “A” - “F” are always displayed in “0.”
In the case of overflow,
lower digits are displayed.
Example: D100 = D1234
4-digit display: 1234
2-digit display: 34
Numerical data
display
Possible
By checking [Num. Display: displays the significant
figures when overflowing] in the [Environment Setting] tab
window of [Unit Setting]
With check mark : Same display mode as with ZM-61E.
Without check mark : Display is given in the manner
shown below.
4-digit display: 1234
2-digit display: --
ZM-71SE Ver. 1.3.0.0 or later
3 ZM-61E -> ZM-62E Conversion