Thank you for purchasing the LCD Control Terminal ZM-62E. Please read the instruction manual carefully, and operate the product with full understanding of its functions and operation methods. For the details of each LCD Control Terminal functions or the panel editing methods, please refer to the instruction manual for the screen edit software.
Safety Precautions Read this user’s manual and attached documents carefully before installation, operation, maintenance and checking in order to use the machine correctly. Understand all of the machine knowledge, safety information, and cautions before starting to use. In this user’s manual, safety precautions are ranked into "danger" and "caution" as follows. Danger : Wrong handling may possibly lead to death or heavy injury. Caution : Wrong handling may possibly lead to medium or light injury.
Contents 1. Hardware Specifications 1. Outline .................................................................................... 1-1 2. Notes on Usage .................................................................... 1-2 3. System Composition ............................................................ 1-4 4. Names of Components ....................................................... 1-7 5. Dimensions and Panel Cut-out ........................................... 1-8 6. Mounting Procedure .............
Hardware Specifications 1. Outline 2. Notes on Usage 3. System Composition 4. Names of Components 5. Dimensions and Panel Cut-out 6. Mounting Procedure 7. Specifications 8. Wiring of Power Supply 9. Serial Connector (CN1) 10. 1 : 1 Communications 11. 1 : n (Multi-drop) Communication 12. n : 1 (Multi-link 2, multi-link) 13. General Purpose Serial Communication 14. Modular Jack 1 & 2 15. Setting of Dip Switches 16. Barcode Reader Interface 17.
1 Outline 1 1-1 Outline LCD Control Terminal ZM-62E is a programmable display unit using a high-luminance EL panel display and touch panel method. With this unit, you can communicate with a programmable logic controller (hereinafter PLC) without a program, display specified data in many ways, and input data in touch panel method. It is the up-graded model of ZM-61E and has a 8.9-inch EL panel. 1. High-luminance EL panel Equipped with a eye-friendly 8.9-inch high-luminance EL panel (TYP: 200cd/m2) 2.
1-2 1 Notes on Usage 2 Notes on Usage Environmental Limits 1. Use ZM-62E at an ambient temperature of 0~50°C, and a relative humidity of 85 %RH. 5. Never install ZM-62E in a place where impacts or vibrations may be transmitted. POWER RUN 50 40 30 20 10 POWER 0 RUN 2. Install a forced fan or an air conditioner to maintain the ambient temperature when it is higher than the above mentioned range. Fan 6.
1 Notes on Usage 3. Never install ZM-62E in the same compartment as high-voltage equipment. The unit should be at least 200 mm away from high-voltage lines or power cables. 1-3 5. In a dry environment, ZM-62E may generate a large amount of static electricity. Therefore, before touching the unit, touch a grounded metallic section to discharge the static electricity. 6. Securely fasten and lock every connector for each cable. Double-check this before turning the power on.
1-4 1 System Composition 3 System Composition Under below is a system configuration and its peripheral devices. System Composition The following illustration shows possible system configurations using ZM-62E.
1 System Composition 1-5 Peripheral Equipment The following options are available for using ZM-62E more effectively. ZM-71SE (Screen edit software for Windows98/NT4.0/Me/ 2000/XP: English version) Application software for editing display data for ZM series. ZM-80C (Data Transfer Cable) 3m Connects ZM-62E to a personal computer, or a personal computer to ZM1REC. ZM-80PC (Printer Cable) 2.5m Connects ZM-62E to a printer.
1-6 1 System Composition ZM-80BC (Cable for Barcode Reader) 3m Connects ZM-62E to a barcode reader. ZM-80MC (Cable for Multi-Link 2 master station) 3m A cable which is used for connecting the ZM- master station and the ** ZM- slave station in the Multi-Link 2 connection. ** 0JUGSSHETZ61E (Protection Sheet) Protects the operation panel surface. Five sheets are included in one package. 0JUWPSHETZ61E (Waterproof Sheet) Protects the operation panel surface from water.
1 Names of Components 4 Names of Components The names of ZM-62E’s parts and their functions are shown below. Front Side POWER RUN Rear Side RUN / STOP L 100240VAC N NC CN1 MJ2 CN2 1. Mounting holes for fixtures 2. Display 3. Power lamp: The red LED lights up when power is on. 4. RUN lamp: The green LED lights up when the unit is working. 5. AC input terminal of power supply 6. RUN/STOP switch: To change the operation modes 7. Serial Connector CN1: for PLC (RS-232C, RS-422) 8.
1-8 1 Dimensions and Panel Cut-out 5 Dimensions and Panel Cut-out Dimensions of ZM-62E Unit : mm Rear View Bottom View RUN / STOP 276 L 95 85 100240VAC N CN1 NC MJ2 10 CN2 Front View Side View 191 203 288 POWER RUN Panel Cut-out of ZM-62E +1 -0 +1 -0 277 192 Unit : mm Panel Cut-out MJ1
1 Mounting Procedure 6 1-9 Mounting Procedure Follow the procedure shown below when you fix a ZM-62E to a mounting board. 1. Cut out the mounting panel (Max. thick: 5 mm) to match the dimensions shown below. Mounting Panel Cut-out +1 277- 0 192 +1-0 -0 192 +1 -0 277 +1 POWER Panel Cut-out RUN 2. Insert 4 pieces of the fixtures attached to ZM-62E into the mounting holes on ZM-62E. Tighten them with the locking screws. Screws : 4 pcs Screw Size : M3 Torque : 0.3~0.
1-10 1 Specifications 7 Specifications General Specifications Specifications Item 100-240V AC Rated Voltage Power Supply Permissible Range of Voltage Permissible Momentary Power Failure within 20ms Demand 25W or less With-stand Voltage Physical Environment 12A, 2.5ms Rushed Electric Current Insulation Resistance Mechanical Working Conditions 85-265V AC (47-440Hz) AC external terminals to FG: 1500V AC per min.
1-11 1 Specifications Display Specifications Item Specifications Display Device High-intensity EL Resolution W x H (dots) 640 x 400 Dot Pitch W x H (mm) 0.3 x 0.3 Effective Display Area W x H (mm) 192 x 120 (8.9 inches) Color Black/orange-yellow + blinking Auto OFF Function Always ON, random setting Backlight Average Life *1 Approx. 30.000 hours POWER Lamp (red) The lamp is lit when the power is supplied. RUN Lamp (green) The lamp is lit when ZM-62E communicates with PLC normally.
1-12 1 Specifications Function Performance Specifications Specifications Item Screens Max. 1024 Screen Memory FP-ROM (flash ROM), Appox. 760kbytes (different from the language) Switches Max.192 per screen Actions of Switch Set, reset, momentary, alternate, to light (possible to press a function switch and a display switch at the same time) Lamps Reverse, blinking, exchange of graphics Max.
1 Specifications 1-13 Touch Panel Specifications Item Specifications Switch Resolution 40 (W) X 20 (H) Form Matrix resistance film form Life of Touch Panel Use of one million times or more Surface treatment Hard coating, anti-glare treatment 5% Interface Specifications Item Specifications Serial Interface RS-232C, RS-422/485 for connecting PLC Asynchronous type (D-sub 25 pins, female) Data length: 7, 8 bits Parity: even, odd, none Stop bit: 1, 2 bits Baud rate: 4800, 9600, 19200, 38400, 5
1-14 1 Specifications Compatible PLC for connection Maker SHARP PLC Model JW10, JW20/20H, JW30H, W70H/100H JW50/70/100, JW50H/70H/100H, J-board MITSUBISHI MELSEC A/Q/FX series, CPU port OMRON SYSMAC C/CV/CQM series FUJI F70/F80H/120H, FLEX-PC CPU/COM, NS/NJ HITACHI HIDEC-H300/700/2000 series/S10 YOKOGAWA FA-M3, FA-500 YASUKAWA MEMOBUS, CP9200SH, MP920/930 MATSUSHITA MEWNET-FP TOYOPUC TOYOPUC-PC2/PC2J, L2 KOYO KOSTAC-SU5/6, SG-8 TOSHIBA TC200 SHINKO SELMART KEYENCE KZ/KV series YA
1 Wiring of Power Supply 8 1-15 Wiring of Power Supply Electrical Wiring Connects the cable for power supply to the terminal on the rear side of ZM-62E. RUN / STOP Type: 100-240VAC L 100240VAC L N CN1 NC Power Supply 100240VAC MJ2 N MJ1 CN2 NC ZM-62E Earth Screw Size M3.5 Clamp Terminal (Unit : mm) Torque (N m) 0.5 (5kgf cm) 8.0MAX 8.0MAX The power source used must be within the allowable voltage fluctuation.
1-16 9 1 Serial Connector (CN1) Serial Connector (CN1) CN1 is used for communicating between a PLC and a ZM-62E (RS-232C, RS-422/485).
1 Serial Connector (CN1) 1-17 Wiring for Communication Never place the communication cable with electric circuits. Never bundle these cables together with other wires in ducts or electric boxes using cord locks. Although it is tempting to bundle all the cables neatly together, this does not necessarily lead to a noise-resistant configuration. It is recommended that the communication cable be independently wired.
1-18 1 Serial Connector (CN1) Terminal Blocks of RS-422/485 Connect ZM-1TC (Terminal Converter) which is the optional equipment to ZM-62E via the serial connector on ZM-62E (CN1) in case of using terminal blocks in RS-422/485 connection. The RS-422 signal wiring of ZM-1TC is connected to the serial connector (CN1). Specify 4-wire connection or 2-wire connection by the dip switch on ZM-1TC (SW1).
1 Serial Connector (CN1) 1-19 Connection Style Three kinds of ZM-62E to PLC connection styles are available as shown below. 1:1 In this style, a single ZM-62E is connected to a single PLC. PLC ZM-62E For details, refer to "10 1 : 1 Communications." POWER RUN To be connected through RS-232C or RS-422 (RS-485) interface. 1 : n (multi-drop) In this style, multiple PLCs are connected to a single ZM-62E. (n = 1 to 31) For details, refer to "11 1 : n Communications.
1-20 1 1 : 1 Communications 10 1 : 1 Communications In this style, a single ZM-62E is connected to a single PLC. PLC ZM-62E POWER RUN To be connected through RS-232C or RS-422 (RS-485) interface. Connection to a PLC About the wiring, communication parameter, etc. in connection between ZM-62E and a PLC, refer to ‘Chapter 2 Connection to Link Units’ of “ZM-42/43/52/72/82 User’s Manual”.
1 1 : n (Multi-drop) Communications 11 1-21 1 : n (Multi-drop) Communication One ZM-62E and multiple PLCs are connected. (n = 1 to 31) ZM-62E POWER RUN To be connected through RS-422/485 interface Max.
1-22 1 1 : n (Multi-drop) Communications Multi-drop Communication (RS-422) Refer to the PLC manual of each manufacturer for connection. The following example describes how one ZM-62E is connected to three PLCs made by MITSUBISHI. See MITSUBISHI’s manual for further details. ZM-62E (CN1) Link unit Link unit Link unit Signal Pin No.
1 n : 1 (Multi-link 2, multi-link) 12 1-23 n : 1 (Multi-link 2, multi-link) Multiple units of ZM- (ZM-62E for example) are connected to a single PLC. ** In this style, there are two kinds of communications. n : 1 Link Communication (Multi-link2) Up to 4 units can be connected to one PLC. * Between a PLC and the ZM-** master station is the same as those for 1:1 communication.
1-24 1 n : 1 (Multi-link 2, multi-link) For the I/F driver, the Multi-Link 2 is supported by the version of 1.100 or later and as for a ZM- master ** station, make sure the hardware version of the unit is as follows. As for ZM-62E and ZM-42/43 series, any version can be used.
1 n : 1 (Multi-link 2, multi-link) 1-25 n : 1 Link Communication (Multi-link) Multiple ZM- ** and a PLC are connected. (n=1 to 31) "ZM-**" 1 "ZM-**" 2 "ZM-**" 3 "ZM-**" n POWER POWER POWER POWER RUN RUN RUN RUN To be connected through RS-485 interface Max. 500 m * Connection as show below is not recommended.
1-26 1 n : 1 (Multi-link 2, multi-link) When multiple ZM- are connected to a link unit of PLC, use the terminal converter (ZM-1TC), the ** optional equipment for RS-485 connection. • Set the dip switch (SW1) of ZM-1TC as 2-wire connection when the ZM-1TC terminal converter is used.
1 General Purpose Serial Communication 13 1-27 General Purpose Serial Communication The ZM-62E can connected with a general purpose computer using the user program (exclusive command use). Refer to ZM (general purpose serial) user’s manual in detail. When a computer and ZM-62E are 1 : 1 RS-232C can use it by less than 15m, and RS-422 (485) can use transmision distance by less than 500m. Interruption processing can be used.
1-28 1 Modular Jack 1 & 2 14 Modular Jack 1 & 2 Modular Jack 1 & 2 (MJ1/2) The right diagram is the pin arrangement and the signal name of modular jack 1 & 2. MJ1/2 12345678 Pin No. 1 2 3 4 5 6 7 8 Signal +SD/RD -SD/RD +5V +5V 0V 0V RD SD Output power supply Max. 150mA Setting of Modular Jack 1 & 2 (MJ1/MJ2) Specify the use of MJ1/MJ2 by the screen edit software (ZM-71SE). Select [Modular] of [System Setting], and then the [Modular Jack] dialog is displayed.
1 Setting of Dip Switches 15 1-29 Setting of Dip Switches Setting of Dip Switches ON 1 2 3 4 Not used 5 6 7 8 The SD terminal resistance between the No. 12 and No. 13 pins of CN1 (serial connector) RD terminal resistance of pin No. 24 and 25 in CN1 (serial connector) Terminal resistance of MJ1 (modular jack 1) Setting of Terminal Resistance • When connecting a PLC and RS-422/485 by 4-wire method, turn DIPSW 7 and 8 on. • When connecting a PLC and RS-422/485 by 2-wire method, turn DISW 7 on.
1-30 1 Barcode Reader Interface 16 Barcode Reader Interface It is possible to receive the signal from a barcode reader by connecting a barcode reader to ZM-62E via the modular jack (MJ1/MJ2) of ZM-62E. 12345678 To connect a barcode reader to ZM-62E via MJ1/MJ2, use the cable which is the cable for barcode reader (ZM-80BC: order product).
1 Printer Interface (CN2) 17 1-31 Printer Interface (CN2) When a printer is connected to ZM-62E via the connector (CN2), it is possible to hard-copy the screen display of ZM-62E, the data sheet, or the sampling data. To connect a printer to ZM-62E, use the parallel interface cable of 36 pins which is optional equipment. (ZM-80PC: 2.5m) * The printer cable for ZM-61E/ZM-70 cannot be used.
1-32 Please use this page freely.
System Menu 1. Operation of Main Menu 2.
2-1 2 Operation of Main Menu 1 Operation of Main Menu When the power of ZM-62E is turned on for the first time, the screen on the below left is displayed. After transferring the screen data to ZM-62E, the following "Main Menu" is displayed. When power is turned on for the first time: "Main Menu" after transferring data ZM-62EM Main Menu 1998- 5 - 5 9: 0: 20 SYS PROG.VER.1.430 I/O Test MemoryCard FONT VER.1.210/1.100/1.000 JAPANESE 32 Comm.Para. I/F DRV VER.1.
2-2 2 Operation of Main Menu Main Menu The "Main Menu" is the system menu for transferring the data between a personal computer and ZM-62E. When the screen data is transferred from a personal computer to ZM-62E, the "Main Menu" or “Comm. Parameter” (see page 2-10) must be displayed. (If [Editor port] is selected for [Modular Jack 1] in the [Modular] of the editing software, it is not necessary to display the "Main Menu.
2 Operation of Main Menu 2-3 A. Self-loop Test Pressing the switch ‘A’ on the “I/O Test” brings to the [Serial Test] screen. This is the test menu to check the signals necessary for ZM-62E to communicate with PLC or a personal computer by using only ZM-62E. Serial Test I/O Test Self-Loop Test Please refer to the manual, "Hardware Specifications".
2-4 2 Operation of Main Menu Test of CTS/RTS Check the [CTS] and [RTS] signals. 1. Jump pins, 4(RTS) and 5(CTS) of CN1. 2. The test is OK if the [CTS] lamp and the [RTS] lamp turn on at the same time that the [RTS] switch is pressed. Similarly, the test is OK if the [CTS] turns off at the same time that the [RTS] is turned off.
2 Operation of Main Menu 2-5 Test of CTS/RTS Check the [CTS] and [RTS] signals. 1. Jump each pin, 14(+RTS) and 19(+CTS), 17(-RTS) and 18(-CTS) of CN1. 2. The test is OK if the [CTS] lamp and the [RTS] lamp turn on at the same time that the [RTS] switch is pressed. Similarly, the test is OK if the [CTS] turns off at the same time that the [RTS] is turned off.
2-6 2 Operation of Main Menu B. Printer Check Check the signal of printer. The test is OK if the test printout is executed satisfactorily when connecting ZM-62E to a printer and pressing this [Printer Check] switch (B). !"#$%&@ !"#$%&@ !"#$%&@ !"#$%&@ !"#$%&@ !"#$%&@ !"#$%&@ 0123456789 0123456789 0123456789 0123456789 0123456789 0123456789 0123456789 ABCDEFGHIJKLMNO ABCDEFGHIJKLMNO ABCDEFGHIJKLMNO ABCDEFGHIJKLMNO ABCDEFGHIJKLMNO ABCDEFGHIJKLMNO ABCDEFGHIJKLMNO C.
2 Operation of Main Menu 2-7 Memory-Card When the [Memory-Card] switch (2.) on the "Main Menu" is pressed, the following "Memory-Card" is displayed. This screen is to transfer the screen data between ZM-62E and a memory-card.
2-8 2 Operation of Main Menu 2) Data Selection, Transfer Pressing each switch leads to selection of the target for data transferring. (Possible to select multiple items.
2 Operation of Main Menu Message Display in Data Transferring If an error occurs during transferring data, the message display window shown on the right is displayed. The kinds and the contents of the messages are as shown below. Message 2-9 Work normally finished O K Contents Work normally finished. The specified operation has been concluded normally. ZM-1REC not connecting ZM-1REC is not connecting when selecting a modular jack.
2-10 2 Operation of Main Menu Comm. Para. When the [Comm. Para.] switch (3.) on the "Main Menu" is pressed, the following "Comm. Param." is displayed. This screen is to show the setting of communication parameter of ZM-62E. Main Menu SYS PROG.VER.1.430 FONT VER.1.210/1.100/1.000 JAPANESE 32 ZM-62EM 1998- 5 - 5 9: 0: 20 Comm. Param. I/O Test Main Menu Screen Data Size : 786432 MemoryCard Error:Retry Time-Out:0.50sec Retry:3 Comm.Para. I/F DRV VER.1.
2 Errors Caused on the ZM-62E 2 2-11 Errors Caused on the ZM-62E Communication Error The followings are the errors which are often caused on the ZM-62E. About any other errors except these errors, refer to ‘Appendix 3 Error’ in “ZM-71SE Instruction Manual (Function).” * When you go to [Comm. Parameter], bring up the [Detail] tab window and set [Continuous] for [Comm. Err. Handling], a screen like the one shown below is displayed. Communication Error Time-Out Screen No. : Received code No.
2-12 2 Errors Caused on the ZM-62E System Error When a system error is detected, the following error screen is displayed.
Editing & Converting Screen 1. Screen Editing of ZM-62E 2.
3 Screen Editing of ZM-62E 1 3-1 Screen Editing of ZM-62E ZM-62E is developed as a higher-level model that replaces ZM-61E. Concerning the items to be taken into consideration when converting the ZM61E data to ZM-62E screen data, refer to “2 ZM-61E --> ZM-62E Conversion.” The following describes the procedure for newly creating the screens using ZM-62E. Setting Procedure A new ZM-62E screen will be created according to the following procedure. 1. Start ZM-71SE (Ver.1.3.0.
3-2 3 Screen Editing of ZM-62E 4. The [Screen [0] Edit] window is displayed. Start screen editing. Restrictions on Creating New Screens with ZM-62E When creating a screen newly using ZM-62E, restrictions indicated below should be taken into consideration. Screen memory About 760k bytes (could increase according to the font to be used) Expansion of memory size is not allowed. Overlap size Although up to 3 overlaps can be displayed simultaneously on a screen, data size for overlapping is limited.
3 Screen Editing of ZM-62E 3-3 Display colors ZM-62E has only two colors - black and orange yellow. The relationship between the color setting at the editor and displayed color on ZM-62E is indicated in the table below.
3-4 3 ZM-61E -> ZM-62E Conversion 2 ZM-61E -> ZM-62E Conversion CONSIDERATIONS ON HARDWARE When you replace ZM-61E with ZM-62E, note the following points. Item Model ZM-61E ZM-62E Effective display area 8.9" 8.
3 ZM-61E -> ZM-62E Conversion Item Model ZM-61E ZM-62E Memory card function Countermeasures Use card recorder ZM-1REC.
3-6 3 ZM-61E -> ZM-62E Conversion CONSIDERATIONS ON SOFTWARE Converting Procedure 1. Start ZM-71SE (Ver.1.3.0.0 or later), then click the [Open] icon, or select [Open] from the [File] menu. Or 2. The [Open a screen data file] dialog is displayed. Change the [Files of type] to [*.ZM]. 3. The ZM-61E screen data files are displayed in this dialog. Specify the ZM-61E screen data file to convert, and click [Open]. 4. The [Edit Model] dialog is displayed. Select [ZM-62E (640*400 8.
3 ZM-61E -> ZM-62E Conversion 3-7 5. The screen edit window is displayed. ZM-61E screen converted for ZM-62E is displayed. Cautions on conversion Conversion contents are largely classified into three categories when converting the ZM-61E screen data into the data for ZM-62E. ZM-61E compatible functions implemented by ZM-71SE Ver. 1.3.0.0 Data converted as ZM-61E compatible data Functions that cannot be converted as ZM-61E compatible data (as of ZM-71SE Ver. 1.3.0.
3-8 Item 3 ZM-61E -> ZM-62E Conversion Model Numerical data display ZM-61E ZM-71SE Ver. 1.3.0.0 or later In the case of overflow, Possible lower digits are displayed. By checking [Num. Display: displays the significant figures when overflowing] in the [Environment Setting] tab Example: D100 = D1234 window of [Unit Setting] 4-digit display: 1234 2-digit display: 34 With check mark : Same display mode as with ZM-61E. Without check mark : Display is given in the manner shown below.
3 ZM-61E -> ZM-62E Conversion Item Model Character 1/ Character 2 3-9 ZM-61E ZM-71SE Ver. 1.3.0.0 or later Usage differs between Character 1 display and Character 2 display. Conversion is made in [Char. Display]. Compatibility to character display on ZM-61E is possible by checking [JIS/ASCII] of the [Detail] tab window. • 1-byte characters and 2-byte characters are distinguished. • For 1-byte characters, NULL code is processed as indicated below.
3-10 3 ZM-61E -> ZM-62E Conversion Data converted as ZM-30 (ZM-61E) compatible data There are notes on converting ZM-30 (ZM-61E) to ZM-42/43/52/72/82 in some functions that are possible in ZM-71SE before adding ZM-62E to ZM-42/43/52/72/82 series line up. Basically, these functions are automatically converted as ZM-30 (ZM-61E) compatible functions. Item Model ZM-30 (ZM-61E) Read/Write Area Background of screen ZM-** (ZM-62E) Possible [Main 1] tab window of [Comm.
3 ZM-61E -> ZM-62E Conversion Item Model Tenkey mode ZM-30 (ZM-61E) 3-11 ZM-** (ZM-62E) [Type: Direct] • [Type: Direct] • For numerical displays on a screen, [Display Function: No] is set. [Type: Indirect] • [Type: Data Display] • [Target Memory: Output Memory] • [Input Item Select: External] • [ZM-30 (ZM-61E) Compatible: (checked)] When there is no overlap, "4" is set. When there is an overlap, the DIV No. for the overlap of ZM-30 (ZM-61E) is set.
3-12 Item 3 ZM-61E -> ZM-62E Conversion Model ZM-30 (ZM-61E) ZM-** (ZM-62E) Character Entry mode Entry mode • [Type: Data Display] • [Command Memory: (same as [Memory] in ZM-30 (ZM-61E)] • [Info. Output Memory: (converted to Write Area n+2)] • [Target Memory: Direct] • [Input Item Select: Internal] • [Detail] tab window [Use Graphic] • For character displays on a screen, [Display Function: Entry Target] is set. Statistics graph mode • The DIV No is converted as follows.
3 Item Model ZM-61E -> ZM-62E Conversion ZM-** (ZM-62E) ZM-30 (ZM-61E) Numeric key mode Memory “n”: [Type: Direct Clear (bit 15) Command] The write flag and displayed value of numeric data entry are cleared at the timing this bit is turned ON (0 --> 1). Memory “n” = H0084 (DEC/4-digit designation) 0 3-13 Input mode [Command Memory]: n Clear (bit 15) When this bit is turned ON, the write flag is cleared, and the display of entered data itself is also cleared.
3-14 3 ZM-61E -> ZM-62E Conversion Model ZM-30 (ZM-61E) Item Sampling (Trend) ZM-** (ZM-62E) Count value is displayed only at ZM. Numeric values [Display Function: Sample Count Display], [Digits: 3] and [Char. Type: 1/4] are set at the lower left area of the graph. Count of the zero position is displayed at the lower The current count is displayed. left area of the graph.
3 ZM-61E -> ZM-62E Conversion Model Item Editing No./name in the memory card mode ZM-30 (ZM-61E) ZM-** (ZM-62E) • Multi-overlap is always used. • Editing is impossible unless [Memory] bit 12 of the numeric keypad entry mode/character entry mode for No./ editing is set ON. • An overlap is deleted when the [ENT] key is pressed and the card No. or the card name /file name/record name is entered In the state after conversion, converted data cannot be used as it is. Screen No.