Specifications
25
<Ver. 2.1>
(2) When there is open space behind the wall and the angle (shape) as shown in the figure can be maintained on
the wall back:
If the back of the wall is tilted at 30 °C or less, the X, Y space temperature
may be set to a limit of 40 °C, regardless of wall thickness.
Special installations (Wall embedding)
MAX 20 mm
X
Y
30°
30°
30°
30°
Exhaust
Beams
Beams
Securing method: Basically, the unit is secured as indicated below. Keep open all areas other than the shaded parts.
The fixing method marked
cannot be used for the unit.
When the unit is fixed on a structure, select a structure of the proper thickness and height. Care
must also be taken regarding the number of fixing bolts to be used (see “3.4.1 Fixing on a structure”).
Bad example of blocking exhaust
<Incorrect><Correct>