Specifications
128
<Ver. 2.1>
A AJN ADJUST NO ×××Exits RS232C adjustment mode (and
switches to normal operational mode).
AJY ADJUST YES
‡ ××Activates RS232C adjustment mode.
B BRT BRIGHTNESS
× ‡‡Adjust BRIGHTNESS.
BHI BLUE HIGH
× ‡‡Adjust BLUE HIGH-LIGHT.
BLW BLUE LOW
× ‡‡Adjust BLUE LOW-LIGHT.
BR1 BAUD RATE 1
×××Sets the RS232C baud rate to 1200bps.
BR2 BAUD RATE 2
×××Sets the RS232C baud rate to 2400bps.
BR3 BAUD RATE 3
×××Sets the RS232C baud rate to 4800bps.
BR4 BAUD RATE 4
×××Sets the RS232C baud rate to 9600bps.
BR5 BAUD RATE 5
×××
Sets the RS232C baud rate to 19200bps.
C CM1 COLOR MODE 1 ‡ ××
Make white-balance adjustment data Mode 1.
CM2 COLOR MODE 2 ‡ ××
Make white-balance adjustment data Mode 2.
CNT CONTRAST × ‡‡Adjust CONTRAST.
COL COLOR
× ‡‡
Adjust COLOR (except for RGB 1 & 2 input).
CFR CLOCK FREQ. × ‡‡Adjust PLL frequency.
(valid only when RGB 1 & 2 are input)
CPH CLOCK PHASE
× ‡‡Adjust PLL phase.
(valid only when RGB 1 & 2 are input)
D DIN DISP NO
‡ ××Disables OSD indication.
DIY DISP YES
‡ ××Enables OSD indication.
DOF DISPLAY OFF
×××Make OSD indication OFF.
DW0 DOWN 10
× — — Make the adjustment value 10 DOWN.
DWn DOWN n
× — — Make the adjustment value nDOWN.
DWF DOWN FULL
× — — Minimize adjustment.
F FRW FRESH WHITE BAL.
×××
Sets all parameter values for picture quality
and white-balance within the selected memory
area 128.
FRP FRESH POSITION ×××
Sets all values for phase adjustment within the
selected memory area 128 (valid only for
RGB 1 & 2 input).
G GHI GREEN HIGH × ‡‡Adjusts GREEN HIGH-LIGHT.
GLW GREEN LOW
× ‡‡Adjusts GREEN LOW-LIGHT.
GWB GET W/B DATA
×××
Outputs values for picture quality and white-
balance adjustment.
GPS GET POSI. DATA ×××
Outputs phase-adjustment values (valid only for RGB
1 & 2 input).
GST GET STATUS ×××Outputs various set values.
GS2 GET STATUS 2
×××Outputs various set values.
Command
name
Name
Validity in
normal
mode
Validity of
number-
direct
command
Function
Validity of
UP/
DOWN
command
Outer control by RS232C
5.3.3 RS232C commands table
Explanation of the tables
• Normal validity
Commands that may be used even when not in RS232C adjustment mode (after sending <AJY> commands)
• Number direct
Commands sent directly followed by numbers 000-255, which immediately become the new adjusted values.
• UP/DOWN command
Commands followed by UPn/DWn (n is any number from 0 to 9) are capable of incrementing adjustment values up
or down in increments of their values.