Instruction manual
8・8
Chapter 8 Monitor (Multipoints Monitor)
8-2 Multipoints Monitor
[1] Function
You can monitor manual data in the data memory or system memory (maximum 128 items).
(Display example)
Data items are renewed by communicating with the PC, and following the assigned monitor type at
each row.
Content
Register the address to be monitored.
●Input method
・You can input the address to be monitored directly in the address cell.
・Right-click the address to be monitored in each of the
Program:Ladder/System/Data/Symbol windows of JW-100SP. In the short
cut menu, select [Send]-[Multipoints Monitor].
・Select the cell including the address to be monitored in the
Program:Ladder window of JW-100SP, and select [Tool]-[Multipoints
Monitor] in the menu bar.
Data items are renewed by communicating with the PC, and following the
assigned monitor type at each line.You can modify the current value of the
register, set/ reset of the timer・counter, and set/ reset of the relay.
●Modify data of register
If you double-click the cell monitoring the register or select the cell and
push the [Enter] key, "data item will change to the input mode. If you input
the [Enter] key after inputting an optional numerical value at the input
mode, you can change data. During the monitoring, you can also change
data of the PC at the same time .
●Set/reset of the relay
if you click on the right side of the mouse on the line monitoring the relay,
the short cut menu that carries set/reset as their items will be displayed. If
you select set/reset by this menu, you can set/reset the relay.
Item
Address
Data
⇒ Refer to the Sample Operation 2.
⇒ Refer to the Sample Operation 1.
(To next page)