Instruction manual

86
Chapter 8 Monitor (Start Monitoring, Stop Monitoring)
[5] Monitor at the [Parameter] window
Monitor parameter
Data items are renewed by communicating with the PC, and following the assigned monitor type.
Modify parameter
If you double-click the data cell, or select the cell and push the [Enter] key, the item will become
the input mode. If you input the [Enter] key after inputting an optional numerical value at the input
mode, the parameter value of the PC will be modified.
Select operation of display
You can operate the following using the [Display] menu or the toolbar for editing data.
Select the display type of the parameter from binary notation/octal notation/decimal notation/
decimal notation (with a plus/minus sign)/hexadecimal notation, or ASCII. This selection works
in the all display area of the parameter.
Select the data length of the parameter from byte/word/double word. This selection is all valid
in the display area of the parameter.
Edit operation
You can cut/copy/paste the selected area by the [Edit] menu , or by the shortcut menu which is
displayed by clicking the right of the mouse.
By modifying the operations described above at the time of the monitor (only when the PC is
stopping), the value of the connected PC will be modified at the same time.
Notes