Instruction manual

712
Chapter 7 Setup Each Data (Setup Option Parameter Tools)
(1) Operation in the area of option parameters
(3) [New]/[Open]/[Close] in the [File] menu
You can set parameters of several option modules in a single option parameter tool.
Select [File]-[New], open the [New] dialog box, and select the type of option module.
You can perform the operations below with the [Display] menu or toolbar for editing data.
Select the data view of parameters from binary notation/octal notation/decimal notation/decimal
notation (with +-)/ hexadecimal notation, or ASCII.
Select the data length of parameters from bytes/words/double words. This selection works in
all the display area of parameters.
In the [Option Parameter Tool] window, the addresses, the data, and the comments are dis-
played.
To edit the data, locate the area with the scroll bar, click the data cell, push the [Enter] key, and
input the numerical values.
You can select one cell with single click.
(2) Selection of display
(4) Model selection in the [File] menu
Select the model of the CU unit you will equip with the option module.
(5) Sending of the [PC] menu
Connect the personal computer to the option module, and read/write/verify the parameters.
Address chart
Data chart
Comment chart
(Example for display: Data link master station)