Instruction manual
6・30
Chapter 6 Program Edit (Ladder Programming)
●●
●●
● Modifying method of increase /decrease value
Depends of the setup of [Double Click] of [Setup]-[Setup Input Type] of the menu bar, the
modifying method of increase /decrease value becomes different.
・In case of setting up "Becomes address input."
If you double click the arrow-shaped cursor at the increase /decrease value position, the
increase /decrease value input mode will be set.
・In case of setting up "Changes instruction at cell."
If you press [↓] key after pressing the [Enter] key, the increase /decrease value input mode
will be set.
(Instruction input mode) (Increase /decrease value input mode)
The initial value of the increase /decrease value is 0, and the input area is -7777 to +7777 (octal
notation). "+" can be omitted.
●●
●●
●
Change increase /decrease value in batch
You can change the increase /decrease value of the ladder circuit of the active [Register Library]
window in batch to the same value .
If you click [Insert]-[Converts Variation in Batch] of the menu bar, [Change Increase /Decrease
Value in Batch] dialog box will be displayed.
If you click [OK] button after checking the "Change to Manual Value" first, and then, inputting the
increase /decrease value, "change in batch" will be executed.
If you click [OK] button after checking "Clear All", all the increase /decrease value will be 0.
(3) Save library file
If you click [File]-[Save As] of the menu bar, the [Register library file] dialog box will be displayed.
If you click [Save] button after setting up the place (directory) to save first, and then inputting the
file name, it will be saved in a file. (file of the extension lb2)
Also, the line comment file is also created at the same time. (file of the extension lbc)