62
Chapter 6 Program Edit (Ladder Programming)
Normal (Address) Display
Display the address (relay address or register address).
In case the address was not assigned when creating a program by the symbol, "*****" will be
displayed at the address part.
Symbol Display
Display the symbol (16 characters).
In case the symbol was not registered when creating a program at the address, the symbol will
not be displayed.
Comment Display (8 characters, 4 lines)
Display the address (relay address or register address) and the comment (28 characters)
within four lines, each of which line can contain 8 characters.
Comments are not shown if you do not register any comments.
You cannot input, modify or delete the comments of application instruction, which is specific to
JW-100SP.
Select Address Display Type
Choose the display type of the ladder program from: Normal (Address) Display, Symbol Display,
Comment Display (8c. 4r), Comment Display (16c, 2r) or Full Display (Address/Symbol/Comment).
Un-assigned address
Relay address
Register address
Symbol
Symbol
Un-registered symbol
Relay address
Comment
Register address
Un-registered comment
Comment on application
instruction
Un-assigned address
Comment