Specifications

129
Appendix II Laser (SE955)
0
Standard data packet. No Function Code 1“FNC1” in the first
character position.
1
Function Code 1“FNC1” in the first character position.
Code 128
2
Function Code 1“FNC1” in the second character position.
0 No check digit processing.
1 Check digit has been verified.
Interleaved 25
3 Check digit has been verified and stripped.
Codabar 0 No check digit processing.
Code 93 0 Always transmit 0.
0 Modulo 10 check digit verified and transmitted. MSI
1 Modulo 10 check digit verified but not transmitted.
Industrial 25
(Discrete 25)
0 Always transmit 0.
0 Standard data packet in full EAN country code format, which
is 13 digits for UPC-A and UPC-E (not including addons).
1 Two-digit addons only.
2 Five-digit addons only.
4 EAN-8 data packet.
UPC/EAN
A UPC-A with Addon 2 barcode, 012345678905-10, is transmitted to the host
as a 21-character string, ]E00012345678905]E110.
Bookland EAN 0 Always transmit 0.
Trioptic Code 39 0 Always transmit 0.