NUAH360

NU-AH360
Maximum power P

360 W
Open-circuit voltage V

47.4 V
Short-circuit current I

9.81 A
Voltage at point of maximum power V

39.0 V
Current at point of maximum power I

9.23 A
Module efficiency
18.6 %
STC = Standard Test Conditions: irradiance 1,000 W/m, AM 1.5, cell temperature 25 °C.
Rated electrical characteristics are within ±10 % of the indicated values of Isc, Voc and 0 to +5 % of Pmax (power measurement tolerance ±3 %).
Reduction of efficiency from an irradiance of 1,000 W/m to 200 W/m (Tmodule = 25 °C) is less than 3%.
NU-AH360
Maximum power P

267.48 W
Open-circuit voltage V

44.0 V
Short-circuit current I

7.93 A
Voltage at point of maximum power V

36.0 V
Current at point of maximum power I

7.43 A
Module operating temperature at 800 W/m irradiance, air temperature of 20 °C, wind speed of 1 m/s. NOCT = 45°C.
Electrical data (NOCT)
Electrical data (STC)
Cells monocrystalline 156.75 mm × 156.75 mm, 72 cells in series
Front glass anti-reflective high transmissive low iron tempered glass, 3.2 mm
Frame anodized aluminium alloy, silver
Connection box IP68, 3 bypass diodes
Cable 4.0 mm, length 1,200 mm
Connector MC4 (Multi Contact, Stäubli Electrical Connectors AG)
Modules per pallet 30 pcs
Pallet size
(L × W × H)
1.995 m × 1.150 m × 1.123 m
Pallet weight 740 kg
Packaging data General data
Length 1,956 mm
Width 992 mm
Depth 35 mm
Weight 22.2 kg
P

-0.39 %/°C
V

-0.30 %/°C
I

0.06 %/°C
Mechanical data
Temperature coefficient
Dimensions (mm)
Maximum system voltage 1,000 VDC
Over-current protection 15 A
Temperature range -40 to +85 °C
Max. mechanical load
(snow / wind)
2,400 Pa
Tested snow load
(IEC61215 test pass*)
5,400 Pa
Limit values
*Please refer to Sharp’s installation manual for details.
Note: Technical data is subject to change without prior notice. Before using Sharp products, please request the latest data sheets from Sharp. Sharp accepts no responsibility for damage to devices which have been equipped with Sharp products on the basis of unverified
information. The specifications may deviate slightly and are not guaranteed. Installation and operating instructions are to be found in the corresponding handbooks, or can be downloaded from www.sharp.eu/solar. This module should not be directly connected to a load.
Contact Sharp
SHARP Electronics GmbH
Energy Solutions
Nagelsweg 33 – 35
20097 Hamburg, Germany
T: +49 (0) 40 / 2376-2436
E: SolarInfo.Europe@sharp.eu
Sharp.co.uk/energysolutions | #SharpBeOriginal
NUAH36EN1118
992mm
941mm
1956mm
1676mm
1176mm
11.5mm
35 mm
35mm
AA
8-3.5x8
1200mm
80mm
80mm
AA
992
35
Grounding hole
Drainage
hole
1,956
Label