NDAR330H
ND-AR330H
Maximum power P
330 W
Open-circuit voltage V
45.5 V
Short-circuit current I
9.40 A
Voltage at point of maximum power V
37.1 V
Current at point of maximum power I
8.9 A
Module efficiency
17.0 %
STC = Standard Test Conditions: irradiance 1,000 W/m, AM 1.5, cell temperature 25 °C.
Rated electrical characteristics are within ±10 % of the indicated values of Isc, Voc and 0 to +5 % of Pmax (power measurement tolerance ±3 %).
Reduction of efficiency from an irradiance of 1,000 W/m to 200 W/m (Tmodule = 25 °C) is less than 3%.
ND-AR330H
Maximum power P
245.9 W
Open-circuit voltage V
43.0 V
Short-circuit current I
7.49 A
Voltage at point of maximum power V
34.5 V
Current at point of maximum power I
7.13 A
NOCT (Nominal Operating Cell Temperature) = 45°C.
Irradiance = 800 W/m, air temperature = 20 °C, wind speed = 1 m/s.
Electrical data (NOCT)
Electrical data (STC)
Cells polycrystalline 156.75 mm × 156.75 mm, 72 cells in series
Front glass low iron tempered ARC glass, 3.2 mm
Frame anodized aluminium alloy, silver
Connection box IP67, 3 bypass diodes
Cable 4.0 mm, length 1,200 mm
Connector Twinsel PV-SY02, IP67
Modules per pallet 27 pcs
Pallet size
(L × W × H)
1.980 m × 1.130 m × 1.130 m
Pallet weight 640 kg
Packaging data General data
Length 1,956 mm
Width 992 mm
Depth 40 mm
Weight 22.0 kg
P
-0.39%/°C
U
-0.32%/°C
I
0.05%/°C
Mechanical data
Temperature coefficient
Dimensions (mm)
Maximum system voltage 1,500 VDC
Over-current protection 15 A
Temperature range -40 to +85 °C
Max. mechanical load
(snow / wind)
2,400 Pa
Limit values
Note: Technical data is subject to change without prior notice. Before using Sharp products, please request the latest data sheets from Sharp. Sharp accepts no responsibility for damage to devices which have been equipped with Sharp products on the basis of unverified
information. The specifications may deviate slightly and are not guaranteed. Installation and operating instructions are to be found in the corresponding handbooks, or can be downloaded from www.sharp.eu/solar. This module should not be directly connected to a load.
Contact Sharp
SHARP Electronics GmbH
Energy Solutions
Nagelsweg 33 – 35
20097 Hamburg, Germany
T: +49 (0) 40 / 2376-2436
E: SolarInfo.Europe@sharp.eu
Sharp.co.uk/energysolutions | #SharpBeOriginal
NDAR33EN0119
AA
AA
(+)(-)
Grounding
hole