Operation Manual, Setup Guide for the Administrator
11
1.2.3 Density Adjustment (Forced Execution)
This performs density adjustment (process control)
forcefully.
1) Select [Density Adjustment (Forced Execution)] in the
Density Adjustment screen.
2) Tap the [Execute] key in the Density Adjustment
(Forced Execution) screen.
3) The following message appears: When image density
adjustment mode is executed, more toner is consumed,
it takes about 20 seconds and the main unit is rebooted
after completion Execute?
Tap the [Execute] key to confirm the message.
4) When the adjustment is completed, a completion
message appears. After a certain period of time lapses,
the machine starts rebooting.
(No requests are accepted by the machine in the period
before the rebooting starts.)
1.3 Fuser Adjustment
Select [Fuser Adjustment] in the Image Quality Adjustment
screen.
1.3.1 Fusing Temperature Setting
This performs setting of fusing temperature.
Fusing performance largely depends on basis weight of
paper. Select proper paper type for fusing temperature
adjustment. When unrecommended paper is used, set
paper property.
See below for detail of adjustment.
Adjustment Detail
Symptoms to adjust the temperature high
・ Poor fusing caused by low temperature (toner is not
on the paper)
・ Not enough gloss is applied.
Symptoms to adjust the temperature low
・ Poor fusing caused by high temperature (surface of
images are rough, Toner may come off)
・ Too much gloss is applied.
・ Paper is curled.
・ Paper is creased.
・ Paper jam occurs in fusing area.
・ Toner blisters occurs.
・ Paper blisters occurs.
Note:
・ When plain paper or recycled paper is used, Set
[Fusing Control Settings] of [Device Control] in [System
Settings].
・ When unrecommend glossy paper is used, set paper
property to print with proper weight of paper setting.
・ When an envelope is not set properly in the tray, poor
fusing or crease may occur.
・ When unrecommended envelope is used, poor fusing
or crease may occur.
1) Select [Fusing Temperature Settings] in the Fusing
Adjustment screen.
2) To change the fusing temperature setting, tap the [+]
and [-] key or use the 10-key pad appears when each
of the textboxes is tapped.
Example of Fusing Temperature Setting screen
Input range: [-10] to [10]
Default: [0] for each
3) Tap the [Register] key to register the setting.
Note:
To reflect the settings, the machine needs to reboot.
When the [Register] key is tapped, a message
appears prompting you to reboot the machine.
4) Tap the [OK] key to reboot the machine.