Service manual

– 21 –
MD-R3
Step 18 Press once the ENTER button. Indication of measurement value [ L B O : _ _ _]
Step 19 Press once the ENTER button. Indication of measurement value [ L E O : _ _ _]
Step 20 Press once the ENTER button. Indication of measurement value [ L F O : _ _ _]
Step 21 Press once the ENTER button. Indication of measurement value [ T C O : _ _ _ _]
Step 22 Press once the ENTER button. Indication of adjustment error sequence No. [ Y O B : _ _ _ _]
Step 23 Press once the ENTER button. Indication of adjustment status [ D I F : _ _ _ _]
Step 24 Press once the ENTER button. Indication of pre-adjustment not completed (00)/completed (4B) [ A D J : _ _ _ _]
Step 25 Press once the MD STOP button. RESULT sub-menu state [ _ R S T _ Y O B I _ ]
Step No.
Setting Method
Remarks Display
: Measurement value, : Adjustment value, : Other various informations
• ressing the REC button causes reversing.
• When the jog key is turned upward while the setting is displayed, the setting increases, and a new setting is stored in RAM.
• When the jog key is turned downward while the setting is displayed, the setting increases, and a new setting is stored in RAM.
Step 1 Testmode STOP state [ t s m e ]
Step 2
Press the ENTER button four times.
RESULT menu [ _ R E S U L T _ _ _ ]
Step 3 Press once the MD PLAY button. Indication of set value [ H A G : _ _ _ ]
Step 4 Press once the ENTER button. Indication of set value [ H B G : _ _ _ ]
Step 5 Press once the ENTER button. Indication of set value [ L A G : _ _ _ ]
Step 6 Press once the ENTER button. Indication of set value [ L B G : _ _ _ ]
Step 7 Press once the ENTER button. Indication of set value [ P E G : _ _ _ ]
Step 8 Press once the ENTER button. Indication of set value [ P F G : _ _ _ ]
Step 9 Press once the ENTER button. Indication of set value [ G E G : _ _ _ ]
Step 10 Press once the ENTER button. Indication of set value [ G F G : _ _ _ ]
Step 11 Press once the ENTER button. Indication of set value [ G C G : _ _ _ _ ]
Step 12 Press once the MD STOP button. RESULT menu state [ _ R E S U L T _ _ _ ]
5. RESULT mode (final adjustment)
Step No.
Setting Method
Remarks Display
: Set value
• ressing the REC button causes reversing.
• When the jog key is turned upward while the setting is displayed, the setting increases, and a new setting is stored in RAM.
• When the jog key is turned downward while the setting is displayed, the setting increases, and a new setting is stored in RAM.
Step 1 Testmode STOP state [ t s m e ]
Step 2
Press the ENTER button five times.
MANUAL auxiliary adjustment mode [ _ M N U _ Y O B I _ ]
Step 3 Press once the MD PLAY button. Initial setting Temperature measuring mode ( : Zone No.) [ T M P : _ _ _ _ ]
Step 4 Press once the ENTER button. Offset "0" setting A signal offset tentative measurement [ H A o : _ _ ]
Step 5 Press once the ENTER button. B signal offset tentative measurement [ H B o : _ _ ]
Step 6 Press once the ENTER button. E signal offset tentative measurement [ H E o : _ _ ]
Step 7 Press once the ENTER button. F signal offset tentative measurement [ H F o : _ _ ]
Step 8 Press once the ENTER button. Offset tentative measurement Laser ON [ L O N : _ _ _ _ _ _ ]
Step 9 Press once the ENTER button. Innermost periphery move RF side FG rough adjustment [ R F g : _ ]
Step 10 Press once the ENTER button. Focus ATT (A signal) tentative setting [ S A g : ]
Step 11 Press once the ENTER button. Focus ATT (B signal) tentative setting [ S B g : ]
Step 12 Press once the ENTER button. RF side pit section TG adjustment [ P T G : _ ]
Step 13 Press once the ENTER button. Pit section COUT level setting [ P C H : _ ]
Step 14 Press once the ENTER button. Outer periphery move RF side groove TG adjustment [ G T G : _ ]
Step 15 Press once the ENTER button. Groove section COUT level setting [ G C H : _ ]
Step 16 Press once the ENTER button. RF side TCRS adjustment [ R C G : _ ]
Step 17 Press once the ENTER button. Tracking ATT (E signal) setting [ S E G : ]
Step 18 Press once the ENTER button. Tracking ATT (F signal) setting [ S F G : ]
Step 19 Press once the ENTER button. Indication of tracking EFMIO measurement [ G M I : _ _ _ ]
Step 20 Press once the ENTER button. RF side pit section FG adjustment [R F G : _ ]
Step 21 Press once the ENTER button. Focus ATT (A signal) setting [ S A G : ]
6. MANUAL auxiliary adjustment mode (only low reflection disc)
Step No.
Setting Method
Remarks Display