Service manual

MD-R3
– 20 –
3. AUTO adjustment mode
Step No.
Setting Method
Remarks Display
Step 1 Testmode STOP state [ t s m e ]
Step 2
Press the ENTER button two times.
AUTO adjustment menu [ A U T O _ A J S T _ ]
Step 3 Press once the MD PLAY button. The slide moves to the innermost periphery, and automatic [ : _ _ _ _ _ _ ]
adjustment is started.
• In case of high reflection disc
changes as follows.
PEGHAG
•In case of low reflection disc changes as follows.
PEGLAGGCGGEGLAG
End of adjustment If adjustment is OK, Step 4.
If adjustment is NG, Step 7.
Step 4 Adjustment value output [ _ C O M P L E T E _ ]
Press the MD PLAY button. STEP 5
Press the MD STOP button. STEP 2
Step 5 Continuous playback (pit section) [ s c ]
Continuous playback (groove section)
[ a c ]
Step 6 Press the DISPLAY button. Continuous playback (groove section) [ a a ]
Press the MD STOP button. STEP 2 AUTO adjustment menu
Step 7 Adjustment value output [ C a n ' t _ A D J . ]
Press the MD STOP button. STEP 2 AUTO adjustment menu
: Adjustment name, : Measurement value, : Address
4. RESULT sub-mode
2. AUTO pre-adjustment mode (Low reflection disc only)
Step No.
Setting Method
Remarks Display
Step 1 Testmode STOP state [ t s m e ]
Step 2 Press once the ENTER button. AUTO pre-adjustment menu [ A U T O ]
Step 3 Press once the MD PLAY button. The slide moves to the innermost periphery, and automatic [ : _ _ _ _ _ _ ]
pre-adjustment is started.
• During automatic adjustment changes as follows.
HAoRFgSAgSBgPTGPCHGTGGCHRCG
SEGRFGSAGHAOHEOTCOLAO
End of adjustment If adjustment is OK, Step 4.
If adjustment is NG, Step 5.
Step 4 Grating adjustment, [ _ C O M P L E T E _ ]
adjustment value output
Press once the MD STOP button. STEP 2
Step 5 Adjustment value output [ C a n ' t _ A D J . ]
Press once the MD STOP button. STEP 2 AUTO pre-adjustment menu
: Adjustment name
Step 1 Testmode STOP state [ t s m e ]
Step 2
Press the ENTER button three times.
RESULT sub-menu [ _ R S T _ Y O B I _ ]
Step 3 Press once the MD PLAY button. Indication of set value [ R F G : _ _ _ _ _ ]
Step 4 Press once the ENTER button. Indication of set value [ R C G : _ _ _ _ _ ]
Step 5 Press once the ENTER button. Indication of set value [ R T G : _ _ _ _ _ ]
Step 6 Press once the ENTER button. Indication of set value [ G T G : _ _ _ _ _ ]
Step 7 Press once the ENTER button. Indication of set value [ P C H : _ _ _ _ ]
Step 8 Press once the ENTER button. Indication of set value [ G C H : _ _ _ _ ]
Step 9 Press once the ENTER button. Indication of set value [ S A G : _ _ _ ]
Step 10 Press once the ENTER button. Indication of set value [ S B G : _ _ _ ]
Step 11 Press once the ENTER button. Indication of set value [ S E G : _ _ _ ]
Step 12 Press once the ENTER button. Indication of set value [ S F G : _ _ _ ]
Step 13 Press once the ENTER button. Indication of measurement value [ H A O : _ _ _]
Step 14 Press once the ENTER button. Indication of measurement value [ H B O : _ _ _]
Step 15 Press once the ENTER button. Indication of measurement value [ H E O : _ _ _]
Step 16 Press once the ENTER button. Indication of measurement value [ H F O : _ _ _]
Step 17 Press once the ENTER button. Indication of measurement value [ L A O : _ _ _]
Step No.
Setting Method
Remarks Display