3. AUTO adjustment mode
Step No.
Setting Method
Remarks Display
Step 1 Testmode STOP state [ t s m e ]
Step 2
Press the ENTER button two times.
AUTO adjustment menu [ A U T O _ A J S T _ ]
Step 3 Press once the MD PLAY button. The slide moves to the innermost periphery, and automatic [ : _ _ _ _ _ _ ]
adjustment is started.
• In case of high reflection disc
changes as follows.
PEG→HAG
•In case of low reflection disc changes as follows.
PEG→LAG→GCG→GEG→LAG
End of adjustment If adjustment is OK, Step 4.
If adjustment is NG, Step 7.
Step 4 Adjustment value output [ _ C O M P L E T E _ ]
Press the MD PLAY button. STEP 5
Press the MD STOP button. STEP 2
Step 5 Continuous playback (pit section) [ s c ]
Continuous playback (groove section)
[ a c ]
Step 6 Press the DISPLAY button. Continuous playback (groove section) [ a a ]
Press the MD STOP button. STEP 2 AUTO adjustment menu
Step 7 Adjustment value output [ C a n ' t _ A D J . ]
Press the MD STOP button. STEP 2 AUTO adjustment menu
• : Adjustment name, : Measurement value, : Address
4. RESULT sub-mode
2. AUTO pre-adjustment mode (Low reflection disc only)
Step No.
Setting Method
Remarks Display
Step 1 Testmode STOP state [ t s m e ]
Step 2 Press once the ENTER button. AUTO pre-adjustment menu [ A U T O ]
Step 3 Press once the MD PLAY button. The slide moves to the innermost periphery, and automatic [ : _ _ _ _ _ _ ]
pre-adjustment is started.
• During automatic adjustment changes as follows.
HAo→RFg→SAg→SBg→PTG→PCH→GTG→GCH→RCG→
SEG→RFG→SAG→HAO→HEO→TCO→LAO
End of adjustment If adjustment is OK, Step 4.
If adjustment is NG, Step 5.
Step 4 Grating adjustment, [ _ C O M P L E T E _ ]
adjustment value output
Press once the MD STOP button. STEP 2
Step 5 Adjustment value output [ C a n ' t _ A D J . ]
Press once the MD STOP button. STEP 2 AUTO pre-adjustment menu
• : Adjustment name
Step 1 Testmode STOP state [ t s m e ]
Step 2
Press the ENTER button three times.
RESULT sub-menu [ _ R S T _ Y O B I _ ]
Step 3 Press once the MD PLAY button. Indication of set value [ R F G : _ _ _ _ _ ]
Step 4 Press once the ENTER button. Indication of set value [ R C G : _ _ _ _ _ ]
Step 5 Press once the ENTER button. Indication of set value [ R T G : _ _ _ _ _ ]
Step 6 Press once the ENTER button. Indication of set value [ G T G : _ _ _ _ _ ]
Step 7 Press once the ENTER button. Indication of set value [ P C H : _ _ _ _ ]
Step 8 Press once the ENTER button. Indication of set value [ G C H : _ _ _ _ ]
Step 9 Press once the ENTER button. Indication of set value [ S A G : _ _ _ ]
Step 10 Press once the ENTER button. Indication of set value [ S B G : _ _ _ ]
Step 11 Press once the ENTER button. Indication of set value [ S E G : _ _ _ ]
Step 12 Press once the ENTER button. Indication of set value [ S F G : _ _ _ ]
Step 13 Press once the ENTER button. Indication of measurement value [ H A O : _ _ _]
Step 14 Press once the ENTER button. Indication of measurement value [ H B O : _ _ _]
Step 15 Press once the ENTER button. Indication of measurement value [ H E O : _ _ _]
Step 16 Press once the ENTER button. Indication of measurement value [ H F O : _ _ _]
Step 17 Press once the ENTER button. Indication of measurement value [ L A O : _ _ _]
Step No.
Setting Method
Remarks Display