4. AUTO FAB adjustment mode
Step No.
Setting Method
Remarks Display
Step 1 Test mode STOP state The AUTO preliminary adjustment should have been completed. [ t s m 1 A e ]
Step 2
Press the EQUALIZER button three times.
AUTO adjustment menu [ _ A U T _ F A B _ _ ]
Step 3
Press the MD PLAY button.
The slide moves to the innermost periphery, and automatic [F A B _ ]
Step 4 Adjustment value output STEP 2 AUTO adjustment [ _ _ ]
Press the
MD STOP
button.
, , : Measurement value
5. EEPROM setting mode
A) Focus setting
Step No.
Setting Method
Display
Step 1 Test mode STOP state [ t s m 1 A e ]
Step 2
Press the EQUALIZER button nine times.
[ E E P R O M_ S E T ]
Step 3
Press the MD PLAY button.
[ _ _ F o c u s _ _ _ ]
Step 4
Press the MD PLAY button.
[F G _ _ _ _ _ _ ]
Step 5
Press the
EQUALIZER
button.
[F F 1 _ _ _ _ _ ]
Step 6
Press the
EQUALIZER
button.
[F F 2 _ _ _ _ _ ]
Step 7
Press the
EQUALIZER
button.
[F Z H L E V _ _ ]
Step 8
Press the
EQUALIZER
button.
[F O K L E V n _ ]
Step 9
Press the
EQUALIZER
button.
[F O K L E V f _ ]
Step 10
Press the
EQUALIZER
button.
[F O K L P F n _ ]
Step 11
Press the
EQUALIZER
button.
[F O K L P F f _ ]
Step 12
Press the
EQUALIZER
button.
[W A I T f _ _ _ ]
Step 13
Press the
EQUALIZER
button.
[D S C J G _ _ _ ]
: Setting value
B) Spin setting
Step No. Setting Method
Display
Step 1 Test mode STOP state [ t s m 1 A e ]
Step 2
Press the EQUALIZER button nine times.
[ E E P R O M_ S E T ]
Step 3
Press the MD PLAY button.
[ _ _ F o c u s _ _ _ ]
Step 4
Press the
EQUALIZER
button.
[ _ S p i n d l e _ _ ]
Step 5
Press the MD PLAY button.
[S P G _ _ _ _ _ ]
Step 6
Press
the
EQUALIZER
bu
tton.
[S P G _ i n _ _ ]
Step 7
Press the
EQUALIZER
button.
[S P G _ m i d _ ]
Step 8
Press the
EQUALIZER
button.
[S P G _ o u t _ ]
Step 9
Press the
EQUALIZER
button.
[S P 1 _ _ _ _ _ ]
Step 10
Press the
EQUALIZER
button.
[S P 2 _ _ _ _ _ ]
Step 11
Press the
EQUALIZER
button.
[S P 3 _ _ _ _ _ ]
Step 12
Press the
EQUALIZER
button.
[S P 4 _ _ _ _ _ ]
Step 13
Press the
EQUALIZER
button.
[S P 5 _ _ _ _ _ ]
Step 14
Press the
EQUALIZER
button.
[S P D L M _ _ ]
: Setting value
C) Tracking setting
Step No.
Setting Method
Display
Step 1 Test mode STOP state [ t s m 1 A e ]
Step 2
Press the EQUALIZER button nine times.
[ E E P R O M_ S E T ]
Step 3
Press the MD PLAY button.
[ _ _ F o c u s _ _ _ ]
Step 4
Press the
EQUALIZER
button two times.
[ _ T r a c k i n g _ ]
Step 5
Press the MD PLAY button.
[T G _ _ _ _ _ _ ]
Step 6
Press the
EQUALIZER
button.
[T F 1 _ _ _ _ _ ]
Step 7
Press the
EQUALIZER
button.
[T F 2 _ _ _ _ _ ]
Step 8
Press the
EQUALIZER
button.
[S V C N T 4 _ _ ]
Step 9
Press the
EQUALIZER
button.
[T R B L V o _ _ ]