Service manual

Revision D 4-23
Troubleshooting: General Fault Isolation
Series 2000 Treadmill
409110-004
Shroud Removal
To remove the treadmill shroud for the internal visual inspection or for
service:
Disconnect the power cord from the rear connector panel.
Remove the screws on the back panel of the shroud and remove
the back panel.
Remove the 2 bolts on each side of the shroud.
Lift off the shroud from the front.
Table 4-8. Visual Inspection List
Area Look for the following problems:
I/O Connectors and Cables Fraying or other damage.• Bent prongs or pins.
Cracked housing.• Loose screws in plugs.
Fuses Type and rating. Replace as necessary.
Interface Cables Excessive tension or wear.• Loose connection.
Strain reliefs out of place.
Circuit Boards Moisture, dust, or debris (top and bottom).• Loose or missing components.
Burn damage or smell of over-heated• Socketed components not firmly seated.
components.• PCB not seated properly in edge connectors.
Solder problems: cracks, splashes on board,
incomplete feed through, prior modifications or
repairs.
Ground Wires/Wiring Loose wires or ground strap connections.• Faulty wiring.
Wires pinched or in vulnerable position.
Mounting Hardware Loose or missing screws or other hardware, especially fasteners used as connections to ground
planes on PCBs.
Power Source Faulty wiring, especially AC outlet.• Circuit not dedicated to system.
(Power source problems can cause static discharge, resetting problems, and noise.)
MD1129-012C
Shroud Side Bolts
Back Panel