Installation
10. Connection Power / Communication
cables, according to the labels marked.
11. See 3.2.1. for Power Cable
specications
a) Connect the ground wire to
terminal 1.
b) Connect the negative line of the
power cable to terminal 2.
c) Connect the positive line of the
power cable to terminal 3.
12. See 3.2.1. for Communication Cable
specications
At rst, connect the ground wire to
terminal 2. Then, make connections
to the other terminals one after
another except terminal 6. Leave
terminal 6 unconnected.
Install protection cover before turning on.
13. Connecting the battery pack to the
inverter
Refer to the installation instructions
for the inverter to connect the power
cable and communication cable to
the inverter. Then, push the circuit
breaker switch up so that it is in the
ON position.