Residential Energy Storage Unit 6.
NOTE The information included in this document is accurate at the time of publication. However, this product is subject to change without prior notice.
Contents 1 Introduction 1.1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 4 4 Main battery pack . . . . . . . . . . . . . . . . . . . . . . . . . . . Expansion battery pack . . . . . . . . . . . . . . . . . . . . . . . . Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 5 6 1.3 2 Safety 2.1 2.2 3 4 5 9 General Precautions for the Battery Pack . . . . . . . . . . . . .
1 Introduction 1.1 Features The RESU® 6.4 EX battery pack has the following features: Photovoltaic system: This battery pack is designed for photovoltaic system compatibility. Battery management system (BMS): The battery pack’s built-in BMS monitors its operation and prevents the battery from operating outside design limitations. See Troubleshooting on page 11. Expandability: The battery capacity can be increased by adding expansion battery packs. Up to two expansion battery packs can be added.
Introduction Charge in progress : While the main pack is charging, the Charge / Dis- charge indicator is lit red. Discharge in progress : While the main pack is discharging, the Charge / Discharge indicator is lit green. Alarm : When the main pack is in a warning or fault state, the Status indicator alternately flashes green and orange. See Troubleshooting on page 11. Expansion battery pack RESU R 6.
Introduction 1.3 Specifications Main battery pack’s dimensions and weight Length 406 mm Width 165 mm Height 664 mm Weight 60 kg Expansion battery pack’s dimensions and weight Length 230 mm Width 165 mm Height 664 mm Weight 32 kg Stat us Ch arge / Di scha rge RE SU R 6.
Introduction Performance Nominal voltage 51.8 V Operating voltage 45.2 V to 58.1 V Nominal capacity with no expansion pack 126 A·h Nominal capacity with 1 expansion pack 189 A·h Nominal capacity with 2 expansion packs 252 A·h Nominal energy with no expansion pack 6.4 kW·h Nominal energy with 1 expansion pack 9.6 kW·h Nominal energy with 2 expansion packs 12.
Introduction Environmental requirements Available operating temperature1) 0°C to 40°C Optimal operating temperature 15°C to 30°C Operating relative humidity 25% to 95% Storage temperature −30°C to 50°C Storage relative humidity 25% to 95% 1) When the ambient temperature is below 10°C, charging and discharging current may be derated to keep the battery safety and lifetime. Communication interface Protocol CAN 2.
2 Safety 2.1 General Precautions for the Battery Pack WARNING Failure to observe the precautions described in this section can cause serious injury to persons or damage to property. Observe the following precautions: • Risks of explosion – Do not subject the battery pack to strong impacts. – Do not crush or puncture the battery pack. – Do not dispose of the battery pack in a fire. • Risks of fire – Do not expose the battery pack to temperatures in excess of 50°C.
Safety 2.2 Warning Labels Main battery pack The nameplate is attached to the right side of the main battery pack, and warning labels are attached to the top and left side. Sta tus Cha rge / Dis cha rge RE SU R 6.4 *$1 < 1 4>& Expansion battery pack @ RESU 6.
3 Troubleshooting 3.1 Starting the Battery Pack Put the battery pack in operation by taking the following steps: 1. Make sure that the circuit breaker switch is in the OFF or Trip position. 2. Move the circuit breaker switch to the ON position to turn on the main battery pack. See if the battery pack is successfully initialized. • The Status indicator on the front should turn on in orange and then change to green in 7 seconds. If it stays orange, contact LG Chem or your distributor.
Troubleshooting 3.3 Main Battery Pack Check the indicators on the front to determine in what state the main battery pack is.
Troubleshooting • BMS Internal Communication • Battery Cell Voltage Imbalance An abnormal state is cleared when the main pack recovers its normal condition. NOTE For a serious fault, if no proper corrective actions are taken by the inverter, the main pack’s circuit breaker automatically trips to protect itself. For example, if the Status indicator stays orange for more than 5 minutes, the circuit breaker trips. Use the monitoring software on the inverter to identify what caused the fault. 3.
4 Emergency Situations The RESU 6.4 EX battery pack comprises multiple batteries that are designed to prevent hazards resulting from failures. However, LG Chem cannot guarantee their absolute safety. 4.1 Leaking Batteries If the battery pack leaks electrolyte, avoid contact with the leaking liquid or gas. If one is exposed to the leaked substance, immediately perform the actions described below. Inhalation: Evacuate the contaminated area, and seek medical attention.
Emergency Situations 3. If the battery pack has caught fire, do not try to extinguish the fire on the battery pack, but evacuate people immediately. WARNING When the battery pack is burning, it produces poisonous gases. 4.3 Wet Batteries If the battery pack is wet or submerged in water, do not let people access it. Contact LG Chem or your distributor for technical assistance. 4.4 Damaged Batteries Damaged batteries are dangerous and must be handled with the utmost care.
5 Warranty 5.1 Warranty Coverage LG Chem protects this product under warranty when this product is installed and used as detailed in this manual. Violating the installation procedure or using this product in any way not described in this manual immediately voids all warranties on this product. 5.
Keep this manual for later use.