Installation Manual
Table Of Contents
- 1 Introduction
- 2 Safety
- 3 Installation
- 4 Troubleshooting
- 5 Emergency Situations
- 6 Warranty
- A Technical Information
Installation
3.2 Installing the Main Battery Pack
Securing the battery pack to a wall
Secure the battery pack to a wall to prevent the battery pack from moving.
The provided mounting brackets cannot support the full weight of the bat-
tery pack. The battery pack must be supported by the oor or an appropriate
platform. When installing the battery pack on a platform, make sure that the
platform is capable of supporting the weight of the battery pack.
20 mm
Make sure to leave a space of at least 20 mm between the battery pack and the
wall. A clearance of at least 20 mm must be left around the battery pack for
proper cooling.
CAUTION
Make sure that the battery pack is at all times exposed to the ambient air.
The battery pack is cooled by natural convection. If the battery pack is
entirely or partially covered or shielded, it may cause the battery pack to
stop operating.
To mount the battery pack to a wall, take the following steps:
6 mm
30 mm
50 mm
25 mm
10 mm
1. Drill holes to suit M6 (¼ in) anchor
bolts in the wall. The drilling depth
should be at least 33 mm.
16