RESU 3.3, 6.5, 10, RESU Plus

Table Of Contents
RESU Plus Installation
5.4.1 Connecting charging cables
1. Loosen the sealing nuts of the large glands.
2. Feed charging cables through the large glands, and connect each charging cable
to its corresponding terminal. Use the terminal block at the lower left for the rst
battery pack, the one at the lower right for the second battery pack, and the one at
the upper for the inverter.
3. Tighten the sealing nuts rmly.
4. Check if the conguration switches on the circuit board are set properly, referring
to Conguring RESU Plus on page 41.
NOTICE
Pay attention not to reverse polarity. Connection with reversed polarity causes se-
vere damage to the battery pack.
To connect other kinds of cables, replace the circuit board and
tighten the screws to a torque of 1 N·m. On the circuit board,
there are network ports, ground points, and terminals to supply
power to the RESU Plus for its operation.
35