Service manual
19
LC-30HV6U
RS232C command table
Command
MSET1001
MOFR~~~~
MOFG~~~~
MOFB~~~~
MGAR~~~~
MGAG~~~~
MGAB~~~~
MINF0000
MINF0001
MINF0002
Function
Used to start the background adjustment.
Used to adjust the value of R OFFSET.
Used to adjust the value of G OFFSET.
Used to adjust the value of B OFFSET.
Used to adjust the value of R GAMMA.
Used to adjust the value of G GAMMA.
Used to adjust the value of B GAMMA.
Used to display the R GAMMA table.
Used to display the B GAMMA table.
Used to display the G GAMMA table.
Remarks
The adjustment ends with a numeric value other than 1001.
Range: 0000 to 0512 (Initial value: 0255)
Range: 0000 to 0512 (Initial value: 0255)
Range: 0000 to 0512 (Initial value: 0255)
Range: 0000 to 0255 (Initial value: 0100)
Range: 0000 to 0255 (Initial value: 0100)
Range: 0000 to 0255 (Initial value: 0100)
(1) Adjusting method using RS-232C
• Get a personal computer with a COM port (RS-232C) equipped with WINDOWS 95/98/me/2000/xp and
a RS-232C crossing cable
• Start up the set with the RS-232C cable connected.
• Start up the terminal software.
(Freeware products available on the Internet can be used.)
• Make setting as shown below.
Baud rate : 9600
Data : 8 bits
Parity : None
Stop : 1 bit
Flow control : None
• If the above setting is made correctly, pressing the "SET/ENTER" key on the PC will make "ERR" appear
on the terminal software.
• In this state, entering a command shown in the table bellow and pressing the "SET/ENTER" key will allow
you to make an adjustment.
If "OK" is displayed on the terminal software after the "SET/ENTER" key is pressed, the command has
been entered successfully.
If "ERR" is displayed, enter the command again.